This HTML5 document contains 36 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n7http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F49777513%3A23220%2F12%3A43915489%21RIV13-MSM-23220___/
n13http://localhost/temp/predkladatel/
n9http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n12http://linked.opendata.cz/resource/domain/vavai/subjekt/
n11http://linked.opendata.cz/ontology/domain/vavai/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n4http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n14http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n15http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n16http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n8http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F49777513%3A23220%2F12%3A43915489%21RIV13-MSM-23220___
rdf:type
skos:Concept n11:Vysledek
dcterms:description
The changes in the supply network configuration can significantly influence the voltage at individual sites during fault events. The paper deals with an impact of the network configuration on the voltage dip magnitude, especially with the impact of a network operated in a radial way, a network with loop lines or parallel lines, and the impact of a spot network or a on-site (local) generator. Equations and graphs concerning with the above issues are derived. Their validation is made on the case of a real 110 kV network, partially meshed. The changes in the supply network configuration can significantly influence the voltage at individual sites during fault events. The paper deals with an impact of the network configuration on the voltage dip magnitude, especially with the impact of a network operated in a radial way, a network with loop lines or parallel lines, and the impact of a spot network or a on-site (local) generator. Equations and graphs concerning with the above issues are derived. Their validation is made on the case of a real 110 kV network, partially meshed.
dcterms:title
Network configuration impact on during-fault voltage in distribution system Network configuration impact on during-fault voltage in distribution system
skos:prefLabel
Network configuration impact on during-fault voltage in distribution system Network configuration impact on during-fault voltage in distribution system
skos:notation
RIV/49777513:23220/12:43915489!RIV13-MSM-23220___
n11:predkladatel
n12:orjk%3A23220
n3:aktivita
n10:I
n3:aktivity
I
n3:dodaniDat
n8:2013
n3:domaciTvurceVysledku
n9:7305087
n3:druhVysledku
n17:O
n3:duvernostUdaju
n14:S
n3:entitaPredkladatele
n7:predkladatel
n3:idSjednocenehoVysledku
153829
n3:idVysledku
RIV/49777513:23220/12:43915489
n3:jazykVysledku
n15:eng
n3:klicovaSlova
local generator; power line; network configuration; short-circuit; sag; voltage dip; power quality; distribution system
n3:klicoveSlovo
n4:distribution%20system n4:power%20quality n4:voltage%20dip n4:short-circuit n4:network%20configuration n4:local%20generator n4:power%20line n4:sag
n3:kontrolniKodProRIV
[4C18CE31E495]
n3:obor
n16:JA
n3:pocetDomacichTvurcuVysledku
1
n3:pocetTvurcuVysledku
1
n3:rokUplatneniVysledku
n8:2012
n3:tvurceVysledku
Tesařová, Miloslava
n13:organizacniJednotka
23220