This HTML5 document contains 45 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n17http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n13http://purl.org/net/nknouf/ns/bibtex#
n11http://localhost/temp/predkladatel/
n20http://linked.opendata.cz/resource/domain/vavai/projekt/
n8http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n6http://linked.opendata.cz/ontology/domain/vavai/
n19https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n16http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F49777513%3A23220%2F07%3A00000002%21RIV08-MPO-23220___/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n10http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n15http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n14http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n21http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n5http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F49777513%3A23220%2F07%3A00000002%21RIV08-MPO-23220___
rdf:type
n6:Vysledek skos:Concept
dcterms:description
This paper deals with the control of voltage source active rectifier operated on the secondary side of medium-frequency transformer. Using of a medium-frequency transformer should save place and weight in a locomotive. The medium-frequency transformer is on the primary side fed by voltage source inverters operated in the six-step mode. This contribution presents the new configuration of the traction drives with MF transformer and especially simulation results of single phase voltage-source active rectifier on the secondary side of MF transformer. Tento článek se zabývá řízením napěťového pulzního usměrňovače který je umýstěn na sekundární straně středofrekvenčního transformátoru. Při použití středofrekvenčního transformátoru dojde k ušetření místa a váhy v lokomotivě. Středofrekvenční transformátor je na primární straně napájen z napěťového střídače, který pracuje s obdélníkovým řízením. Tento příspěvek představuje novou konfiguraci trakčního pohonu se středofrekvenčním transformátorem, příspěvek je zvláště zaměřen na simulaci napěťového pulzního usměrňovače na sekundární straně středofrekvenčního transfor This paper deals with the control of voltage source active rectifier operated on the secondary side of medium-frequency transformer. Using of a medium-frequency transformer should save place and weight in a locomotive. The medium-frequency transformer is on the primary side fed by voltage source inverters operated in the six-step mode. This contribution presents the new configuration of the traction drives with MF transformer and especially simulation results of single phase voltage-source active rectifier on the secondary side of MF transformer.
dcterms:title
Simulation of Single-Phase Voltage Source Active Rectifier for Traction Drive Supplied Via Medium-Frequency Transformer Simulace jednofázového napěťového pulzního usměrňovače pro trakční pohon napájeného ze středofrekvenčního transformátoru Simulation of Single-Phase Voltage Source Active Rectifier for Traction Drive Supplied Via Medium-Frequency Transformer
skos:prefLabel
Simulace jednofázového napěťového pulzního usměrňovače pro trakční pohon napájeného ze středofrekvenčního transformátoru Simulation of Single-Phase Voltage Source Active Rectifier for Traction Drive Supplied Via Medium-Frequency Transformer Simulation of Single-Phase Voltage Source Active Rectifier for Traction Drive Supplied Via Medium-Frequency Transformer
skos:notation
RIV/49777513:23220/07:00000002!RIV08-MPO-23220___
n3:strany
17-20
n3:aktivita
n14:P
n3:aktivity
P(FT-TA2/035)
n3:dodaniDat
n5:2008
n3:domaciTvurceVysledku
n8:6823033 n8:3186830
n3:druhVysledku
n18:D
n3:duvernostUdaju
n12:S
n3:entitaPredkladatele
n16:predkladatel
n3:idSjednocenehoVysledku
449969
n3:idVysledku
RIV/49777513:23220/07:00000002
n3:jazykVysledku
n15:eng
n3:klicovaSlova
Single phase voltage-source active rectifier; Control of source active rectifier; New configuration of the traction drive
n3:klicoveSlovo
n10:Single%20phase%20voltage-source%20active%20rectifier n10:Control%20of%20source%20active%20rectifier n10:New%20configuration%20of%20the%20traction%20drive
n3:kontrolniKodProRIV
[A096F1632979]
n3:mistoKonaniAkce
Plzeň
n3:mistoVydani
Pilsen
n3:nazevZdroje
Applied Electronics 2007
n3:obor
n21:JA
n3:pocetDomacichTvurcuVysledku
2
n3:pocetTvurcuVysledku
2
n3:projekt
n20:FT-TA2%2F035
n3:rokUplatneniVysledku
n5:2007
n3:tvurceVysledku
Peroutka, Zdeněk Blahník, Vojtěch
n3:typAkce
n17:WRD
n3:zahajeniAkce
2007-01-01+01:00
s:numberOfPages
4
n13:hasPublisher
Západočeská univerzita v Plzni
n19:isbn
978-80-7043-537-3
n11:organizacniJednotka
23220