This HTML5 document contains 47 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n18http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n20http://localhost/temp/predkladatel/
n15http://purl.org/net/nknouf/ns/bibtex#
n17http://linked.opendata.cz/resource/domain/vavai/projekt/
n12http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n13http://linked.opendata.cz/ontology/domain/vavai/
n16https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n4http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n21http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F49777513%3A23220%2F03%3A00000028%21RIV%2F2004%2FGA0%2F232204%2FN/
n5http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n19http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n7http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n6http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n9http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n8http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n10http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F49777513%3A23220%2F03%3A00000028%21RIV%2F2004%2FGA0%2F232204%2FN
rdf:type
skos:Concept n13:Vysledek
dcterms:description
The knowledge about the occurrence of voltage dips in a network can be obtained through the use of power quality monitors or by means of prediction methods. For assessment of the number of voltage dips, the method of fault positions could be used. The m ethod was applied to a real 110 kV grid. The expected number of dips and distribution of remaining voltage in the chosen substation were calculated. The results were compared with the outcome of the voltage dip monitoring. The knowledge about the occurrence of voltage dips in a network can be obtained through the use of power quality monitors or by means of prediction methods. For assessment of the number of voltage dips, the method of fault positions could be used. The m ethod was applied to a real 110 kV grid. The expected number of dips and distribution of remaining voltage in the chosen substation were calculated. The results were compared with the outcome of the voltage dip monitoring.
dcterms:title
Comparison of the voltage dip assessment with the monitoring results Comparison of the voltage dip assessment with the monitoring results
skos:prefLabel
Comparison of the voltage dip assessment with the monitoring results Comparison of the voltage dip assessment with the monitoring results
skos:notation
RIV/49777513:23220/03:00000028!RIV/2004/GA0/232204/N
n4:strany
201-205
n4:aktivita
n6:P
n4:aktivity
P(GP102/03/P091)
n4:dodaniDat
n10:2004
n4:domaciTvurceVysledku
n12:7305087
n4:druhVysledku
n8:D
n4:duvernostUdaju
n19:S
n4:entitaPredkladatele
n21:predkladatel
n4:idSjednocenehoVysledku
601791
n4:idVysledku
RIV/49777513:23220/03:00000028
n4:jazykVysledku
n7:eng
n4:klicovaSlova
distribution system;power quality; voltage dip;sag;exposed area;short-circuit;method of fault positions;prediction
n4:klicoveSlovo
n5:prediction n5:method%20of%20fault%20positions n5:sag n5:voltage%20dip n5:distribution%20system n5:power%20quality n5:exposed%20area n5:short-circuit
n4:kontrolniKodProRIV
[3C4693BAF8A4]
n4:mistoKonaniAkce
Krakov
n4:mistoVydani
Lodz
n4:nazevZdroje
Electrical Power Quality and Utilisation
n4:obor
n9:JE
n4:pocetDomacichTvurcuVysledku
1
n4:pocetTvurcuVysledku
1
n4:pocetUcastnikuAkce
0
n4:pocetZahranicnichUcastnikuAkce
0
n4:projekt
n17:GP102%2F03%2FP091
n4:rokUplatneniVysledku
n10:2003
n4:tvurceVysledku
Tesařová, Miloslava
n4:typAkce
n18:WRD
n4:zahajeniAkce
2003-09-17+02:00
s:numberOfPages
5
n15:hasPublisher
Technical University of Lodz
n16:isbn
83-914296-7-9
n20:organizacniJednotka
23220