This HTML5 document contains 39 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n15http://localhost/temp/predkladatel/
n17http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n10http://linked.opendata.cz/resource/domain/vavai/subjekt/
n7http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F47813059%3A19510%2F11%3A%230000142%21RIV12-MSM-19510___/
n9http://linked.opendata.cz/ontology/domain/vavai/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n5http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n8http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n16http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n18http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n11http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n13http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n6http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n14http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F47813059%3A19510%2F11%3A%230000142%21RIV12-MSM-19510___
rdf:type
skos:Concept n9:Vysledek
dcterms:description
This paper deals with problematic of Electromagnetic Compatibility of Implantable Pacemaker. The ambient electromagnetic field can negatively influence the pacemaker functionality and also the wireless communication between its programmer and device. Electromagnetic compatibility parameters are tested by direct induction of interference signal to the inputs of cardiac pacemaker according to technical specification. The experimental tests were also made by generating of interference radio frequency signals to disturb the wireless telemetry communication. This paper deals with problematic of Electromagnetic Compatibility of Implantable Pacemaker. The ambient electromagnetic field can negatively influence the pacemaker functionality and also the wireless communication between its programmer and device. Electromagnetic compatibility parameters are tested by direct induction of interference signal to the inputs of cardiac pacemaker according to technical specification. The experimental tests were also made by generating of interference radio frequency signals to disturb the wireless telemetry communication.
dcterms:title
Measurement and analysis EMC parameters of implantable pacemaker Measurement and analysis EMC parameters of implantable pacemaker
skos:prefLabel
Measurement and analysis EMC parameters of implantable pacemaker Measurement and analysis EMC parameters of implantable pacemaker
skos:notation
RIV/47813059:19510/11:#0000142!RIV12-MSM-19510___
n9:predkladatel
n10:orjk%3A19510
n5:aktivita
n11:S n11:N
n5:aktivity
N, S
n5:cisloPeriodika
5
n5:dodaniDat
n14:2012
n5:domaciTvurceVysledku
n17:6855075
n5:druhVysledku
n13:J
n5:duvernostUdaju
n16:S
n5:entitaPredkladatele
n7:predkladatel
n5:idSjednocenehoVysledku
211009
n5:idVysledku
RIV/47813059:19510/11:#0000142
n5:jazykVysledku
n18:eng
n5:klicovaSlova
Measurement, Implantable Pacemaker, Electromagnetic Compatibility, Disturbing Signal
n5:klicoveSlovo
n8:Implantable%20Pacemaker n8:Disturbing%20Signal n8:Measurement n8:Electromagnetic%20Compatibility
n5:kodStatuVydavatele
PL - Polská republika
n5:kontrolniKodProRIV
[305435507379]
n5:nazevZdroje
Przegląd Elektrotechniczny
n5:obor
n6:FS
n5:pocetDomacichTvurcuVysledku
1
n5:pocetTvurcuVysledku
3
n5:rokUplatneniVysledku
n14:2011
n5:svazekPeriodika
87
n5:tvurceVysledku
Korpas, David
s:issn
0033-2097
s:numberOfPages
4
n15:organizacniJednotka
19510