This HTML5 document contains 42 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n6http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n20http://purl.org/net/nknouf/ns/bibtex#
n10http://localhost/temp/predkladatel/
n16http://linked.opendata.cz/resource/domain/vavai/projekt/
n14http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n13http://linked.opendata.cz/ontology/domain/vavai/
n12https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
n7http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F46747885%3A24220%2F09%3A%230001251%21RIV10-GA0-24220___/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n11http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n19http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n15http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n21http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n17http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F46747885%3A24220%2F09%3A%230001251%21RIV10-GA0-24220___
rdf:type
n13:Vysledek skos:Concept
dcterms:description
This article deals with an unequal distribution of current density in a low voltage bus bar with higher load of current. The skin effect appears even in case of low frequency 50Hz by higher current. The cross-section of bus bars in thousands amperes is sizeable and therefore the surface action affects transmission losses. Essential theory and simulation are described in this article. Presented examples demonstrate the importance of this problem in practice. This article deals with an unequal distribution of current density in a low voltage bus bar with higher load of current. The skin effect appears even in case of low frequency 50Hz by higher current. The cross-section of bus bars in thousands amperes is sizeable and therefore the surface action affects transmission losses. Essential theory and simulation are described in this article. Presented examples demonstrate the importance of this problem in practice.
dcterms:title
The skin effect within three phase 50 Hz power net with high current load The skin effect within three phase 50 Hz power net with high current load
skos:prefLabel
The skin effect within three phase 50 Hz power net with high current load The skin effect within three phase 50 Hz power net with high current load
skos:notation
RIV/46747885:24220/09:#0001251!RIV10-GA0-24220___
n3:aktivita
n19:S n19:P
n3:aktivity
P(GD102/08/H081), S
n3:dodaniDat
n17:2010
n3:domaciTvurceVysledku
n14:4896483 n14:1621203
n3:druhVysledku
n18:D
n3:duvernostUdaju
n4:S
n3:entitaPredkladatele
n7:predkladatel
n3:idSjednocenehoVysledku
341515
n3:idVysledku
RIV/46747885:24220/09:#0001251
n3:jazykVysledku
n15:eng
n3:klicovaSlova
Skin effect, bus bar, high current load
n3:klicoveSlovo
n11:high%20current%20load n11:Skin%20effect n11:bus%20bar
n3:kontrolniKodProRIV
[90C89D3BAC6A]
n3:mistoKonaniAkce
Mondragon
n3:mistoVydani
Mondragon
n3:nazevZdroje
ECMS
n3:obor
n21:JA
n3:pocetDomacichTvurcuVysledku
2
n3:pocetTvurcuVysledku
2
n3:projekt
n16:GD102%2F08%2FH081
n3:rokUplatneniVysledku
n17:2009
n3:tvurceVysledku
Richter, Aleš Truhlář, Martin
n3:typAkce
n6:WRD
n3:zahajeniAkce
2009-01-01+01:00
s:numberOfPages
6
n20:hasPublisher
MU. Mondrago Unibertsitateko
n12:isbn
978-84-608-0941-8
n10:organizacniJednotka
24220