This HTML5 document contains 50 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n24http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n15http://purl.org/net/nknouf/ns/bibtex#
n14http://localhost/temp/predkladatel/
n16http://linked.opendata.cz/resource/domain/vavai/projekt/
n11http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n19http://linked.opendata.cz/resource/domain/vavai/subjekt/
n18http://linked.opendata.cz/ontology/domain/vavai/
n10http://linked.opendata.cz/resource/domain/vavai/zamer/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
rdfshttp://www.w3.org/2000/01/rdf-schema#
n4http://linked.opendata.cz/ontology/domain/vavai/riv/
n13http://bibframe.org/vocab/
n21http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F46747885%3A24210%2F12%3A%230005601%21RIV14-GA0-24210___/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n5http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n8http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n20http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n7http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n22http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n9http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n17http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F46747885%3A24210%2F12%3A%230005601%21RIV14-GA0-24210___
rdf:type
skos:Concept n18:Vysledek
rdfs:seeAlso
http://www.epj-conferences.org/articles/epjconf/pdf/2012/07/epjconf_EFM2011_02017.pdf
dcterms:description
The article describes experimental setup for investigation of the impact load from collapsing cavitation bubble on a solid wall. A vapour bubble is generated inside a cubic chamber by local heating of water inside a thin channel in a button. The bubble collapse is initiated by a piezoelectric actuator attached to the flexible wall of the chamber. A laser diode with a linear CCD sensor are used to detect the bubble position during its buoyancy-driven rise to the upper wall of the chamber. The bubble collapse impact load is measured using a PVDF piezoelectric transducer glued to the upper wall of the chamber and recorded by high-speed CCD camera illuminated by a high-power LED diode. The pressure inside the chamber is measured by the dynamic pressure transducer. All the system components are controlled and synchronized by an oscilloscope and pulse generator using the LabView software. The article describes experimental setup for investigation of the impact load from collapsing cavitation bubble on a solid wall. A vapour bubble is generated inside a cubic chamber by local heating of water inside a thin channel in a button. The bubble collapse is initiated by a piezoelectric actuator attached to the flexible wall of the chamber. A laser diode with a linear CCD sensor are used to detect the bubble position during its buoyancy-driven rise to the upper wall of the chamber. The bubble collapse impact load is measured using a PVDF piezoelectric transducer glued to the upper wall of the chamber and recorded by high-speed CCD camera illuminated by a high-power LED diode. The pressure inside the chamber is measured by the dynamic pressure transducer. All the system components are controlled and synchronized by an oscilloscope and pulse generator using the LabView software.
dcterms:title
DESIGN OF EXPERIMENTAL SETUP FOR INVESTIGATION OF CAVITATION BUBBLE COLLAPSE CLOSE TO A SOLID WALL DESIGN OF EXPERIMENTAL SETUP FOR INVESTIGATION OF CAVITATION BUBBLE COLLAPSE CLOSE TO A SOLID WALL
skos:prefLabel
DESIGN OF EXPERIMENTAL SETUP FOR INVESTIGATION OF CAVITATION BUBBLE COLLAPSE CLOSE TO A SOLID WALL DESIGN OF EXPERIMENTAL SETUP FOR INVESTIGATION OF CAVITATION BUBBLE COLLAPSE CLOSE TO A SOLID WALL
skos:notation
RIV/46747885:24210/12:#0005601!RIV14-GA0-24210___
n18:predkladatel
n19:orjk%3A24210
n4:aktivita
n7:Z n7:P
n4:aktivity
P(GAP101/10/1428), Z(MSM4674788501)
n4:dodaniDat
n17:2014
n4:domaciTvurceVysledku
n11:8994390 n11:7065280
n4:druhVysledku
n22:D
n4:duvernostUdaju
n8:S
n4:entitaPredkladatele
n21:predkladatel
n4:idSjednocenehoVysledku
130328
n4:idVysledku
RIV/46747885:24210/12:#0005601
n4:jazykVysledku
n20:eng
n4:klicovaSlova
cavitation; bubble; collapse; solid wall
n4:klicoveSlovo
n5:cavitation n5:collapse n5:bubble n5:solid%20wall
n4:kontrolniKodProRIV
[3259635BDFB5]
n4:mistoKonaniAkce
Czech Republic
n4:mistoVydani
FRANCIE
n4:nazevZdroje
EPJ Web of Conferences
n4:obor
n9:JE
n4:pocetDomacichTvurcuVysledku
2
n4:pocetTvurcuVysledku
4
n4:projekt
n16:GAP101%2F10%2F1428
n4:rokUplatneniVysledku
n17:2012
n4:tvurceVysledku
Müller, Miloš Zima, Patrik Unger, Jiří Živný, Martin
n4:typAkce
n24:WRD
n4:wos
000304449600120
n4:zahajeniAkce
2011-01-01+01:00
n4:zamer
n10:MSM4674788501
s:issn
2100-014X
s:numberOfPages
4
n13:doi
10.1051/epjconf/20122502017
n15:hasPublisher
E D P SCIENCES
n14:organizacniJednotka
24210