This HTML5 document contains 46 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n13http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n18http://purl.org/net/nknouf/ns/bibtex#
n8http://localhost/temp/predkladatel/
n21http://linked.opendata.cz/resource/domain/vavai/projekt/
n9http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n17http://linked.opendata.cz/ontology/domain/vavai/
n15http://linked.opendata.cz/resource/domain/vavai/zamer/
n14https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n4http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n20http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F46747885%3A24210%2F10%3A%230001632%21RIV11-GA0-24210___/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n7http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n19http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n5http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n22http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n16http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n12http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F46747885%3A24210%2F10%3A%230001632%21RIV11-GA0-24210___
rdf:type
skos:Concept n17:Vysledek
dcterms:description
The article describes experimental setup for investigation of the impact load from collapsing cavitation bubble on a solid wall. A vapour bubble is generated inside a cubic chamber by local heating of water inside a thin channel in a button. The bubble collapse is initiated by a piezoelectric actuator attached to the flexible wall of the chamber. A laser diode with a linear CCD sensor are used to detect the bubble position during its buoyancy-driven rise to the upper wall of the chamber. The bubble collapse impact load is measured using a PVDF piezoelectric transducer glued to the upper wall of the chamber and recorded by high-speed CCD camera illuminated by a high-power LED diode. The pressure inside the chamber is measured by the dynamic pressure transducer. All the system components are controlled and synchronized by an oscilloscope and pulse generator using the LabView software. The article describes experimental setup for investigation of the impact load from collapsing cavitation bubble on a solid wall. A vapour bubble is generated inside a cubic chamber by local heating of water inside a thin channel in a button. The bubble collapse is initiated by a piezoelectric actuator attached to the flexible wall of the chamber. A laser diode with a linear CCD sensor are used to detect the bubble position during its buoyancy-driven rise to the upper wall of the chamber. The bubble collapse impact load is measured using a PVDF piezoelectric transducer glued to the upper wall of the chamber and recorded by high-speed CCD camera illuminated by a high-power LED diode. The pressure inside the chamber is measured by the dynamic pressure transducer. All the system components are controlled and synchronized by an oscilloscope and pulse generator using the LabView software.
dcterms:title
Design of experimental setup for investigation of cavitation bubble collapse close to a solid wall Design of experimental setup for investigation of cavitation bubble collapse close to a solid wall
skos:prefLabel
Design of experimental setup for investigation of cavitation bubble collapse close to a solid wall Design of experimental setup for investigation of cavitation bubble collapse close to a solid wall
skos:notation
RIV/46747885:24210/10:#0001632!RIV11-GA0-24210___
n4:aktivita
n5:Z n5:P
n4:aktivity
P(GAP101/10/1428), Z(MSM4674788501)
n4:dodaniDat
n12:2011
n4:domaciTvurceVysledku
n9:8994390 n9:7065280 n9:6614736
n4:druhVysledku
n16:D
n4:duvernostUdaju
n7:S
n4:entitaPredkladatele
n20:predkladatel
n4:idSjednocenehoVysledku
253533
n4:idVysledku
RIV/46747885:24210/10:#0001632
n4:jazykVysledku
n19:eng
n4:klicovaSlova
cavitation; bubble; collapse
n4:klicoveSlovo
n10:collapse n10:cavitation n10:bubble
n4:kontrolniKodProRIV
[D4EFC814A12A]
n4:mistoKonaniAkce
Ještěd, Liberec
n4:mistoVydani
Technická univerzita v Liberci
n4:nazevZdroje
International Conference Experimental Fluid Mechanics 2010 Conference Proceedings
n4:obor
n22:BK
n4:pocetDomacichTvurcuVysledku
3
n4:pocetTvurcuVysledku
4
n4:projekt
n21:GAP101%2F10%2F1428
n4:rokUplatneniVysledku
n12:2010
n4:tvurceVysledku
Živný, Martin Müller, Miloš Zima, Patrik Unger, Jiří
n4:typAkce
n13:WRD
n4:zahajeniAkce
2010-01-01+01:00
n4:zamer
n15:MSM4674788501
s:numberOfPages
852
n18:hasPublisher
Technická univerzita v Liberci
n14:isbn
9788073726706
n8:organizacniJednotka
24210