This HTML5 document contains 42 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n20http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n12http://purl.org/net/nknouf/ns/bibtex#
n16http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n7http://linked.opendata.cz/resource/domain/vavai/projekt/
n19http://linked.opendata.cz/resource/domain/vavai/subjekt/
n17http://linked.opendata.cz/ontology/domain/vavai/
n18https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n10http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F26823357%3A_____%2F11%3A%230000034%21RIV13-MPO-26823357/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n4http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n21http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n13http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n8http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n14http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n9http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n11http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F26823357%3A_____%2F11%3A%230000034%21RIV13-MPO-26823357
rdf:type
n17:Vysledek skos:Concept
dcterms:description
It is shown that a system with counter-current in- and outflow (U-type flow) in heat exchangers can lead to an even distribution in branched systems with given high temperature. The irregularity of flow distribution in branched systems can be reduced by optimization of the feeder and header diameters. The computation formulas for the feeder and header diameters are given. It is shown that a system with counter-current in- and outflow (U-type flow) in heat exchangers can lead to an even distribution in branched systems with given high temperature. The irregularity of flow distribution in branched systems can be reduced by optimization of the feeder and header diameters. The computation formulas for the feeder and header diameters are given.
dcterms:title
The complement to tube - system design The complement to tube - system design
skos:prefLabel
The complement to tube - system design The complement to tube - system design
skos:notation
RIV/26823357:_____/11:#0000034!RIV13-MPO-26823357
n17:predkladatel
n19:ico%3A26823357
n3:aktivita
n8:P n8:V
n3:aktivity
P(FR-TI1/073), V
n3:dodaniDat
n11:2013
n3:domaciTvurceVysledku
n16:4353021 n16:9421009
n3:druhVysledku
n14:D
n3:duvernostUdaju
n21:S
n3:entitaPredkladatele
n10:predkladatel
n3:idSjednocenehoVysledku
191369
n3:idVysledku
RIV/26823357:_____/11:#0000034
n3:jazykVysledku
n13:eng
n3:klicovaSlova
U-type flow system; even flow distribution; optimization of diameters
n3:klicoveSlovo
n4:even%20flow%20distribution n4:optimization%20of%20diameters n4:U-type%20flow%20system
n3:kontrolniKodProRIV
[1B4A600C0F3A]
n3:mistoKonaniAkce
Žďár nad Sázavou
n3:nazevZdroje
Engineering mechanics
n3:obor
n9:JE
n3:pocetDomacichTvurcuVysledku
2
n3:pocetTvurcuVysledku
3
n3:projekt
n7:FR-TI1%2F073
n3:rokUplatneniVysledku
n11:2011
n3:tvurceVysledku
Jirouš, František Stárek, Kamil Kupsa, Vladimír
n3:typAkce
n20:EUR
n3:zahajeniAkce
2011-05-09+02:00
s:numberOfPages
4
n12:hasPublisher
Neuveden
n18:isbn
978-80-87012-33-8