This HTML5 document contains 38 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n16http://linked.opendata.cz/resource/domain/vavai/projekt/
n14http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n9http://linked.opendata.cz/resource/domain/vavai/subjekt/
n8http://linked.opendata.cz/ontology/domain/vavai/
n7http://linked.opendata.cz/ontology/domain/vavai/riv/kodPristupu/
skoshttp://www.w3.org/2004/02/skos/core#
n4http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n6http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n15http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n18http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n11http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n13http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n10http://reference.data.gov.uk/id/gregorian-year/
n5http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F15503933%3A_____%2F11%3A%230000016%21RIV12-MPO-15503933/

Statements

Subject Item
n2:RIV%2F15503933%3A_____%2F11%3A%230000016%21RIV12-MPO-15503933
rdf:type
n8:Vysledek skos:Concept
dcterms:description
The Inter Stand Cooling at wide strip hot mills partakes fundamentally in reaching and maintaining the required exit rolling temperature (ERT). Thus it enables to reach better and more homogeneous mechanical properties of a strip, particularly in micro alloyed steels. ERT can be maintained constant on the whole strip length, even when transfer bar temperature oscillates due to skid marks in slab or other reasons. Very important is the possibility to increase the mill production so that it enables to roll at higher speed or speed up. For the correct function of the Inter Stand Cooling it is necessary to fulfill two basic requirements – to keep at disposition an optimal hardware (cooling headers with sufficient cooling power including the possibility of fast and fluent regulation of flow rate) and the advanced control software, both for cooling setup, feed forward and feedback control. The Inter Stand Cooling at wide strip hot mills partakes fundamentally in reaching and maintaining the required exit rolling temperature (ERT). Thus it enables to reach better and more homogeneous mechanical properties of a strip, particularly in micro alloyed steels. ERT can be maintained constant on the whole strip length, even when transfer bar temperature oscillates due to skid marks in slab or other reasons. Very important is the possibility to increase the mill production so that it enables to roll at higher speed or speed up. For the correct function of the Inter Stand Cooling it is necessary to fulfill two basic requirements – to keep at disposition an optimal hardware (cooling headers with sufficient cooling power including the possibility of fast and fluent regulation of flow rate) and the advanced control software, both for cooling setup, feed forward and feedback control.
dcterms:title
An Effective InterStand Cooling in Hot Strip Mill An Effective InterStand Cooling in Hot Strip Mill
skos:prefLabel
An Effective InterStand Cooling in Hot Strip Mill An Effective InterStand Cooling in Hot Strip Mill
skos:notation
RIV/15503933:_____/11:#0000016!RIV12-MPO-15503933
n8:predkladatel
n9:ico%3A15503933
n4:aktivita
n11:P
n4:aktivity
P(FR-TI1/435)
n4:dodaniDat
n10:2012
n4:domaciTvurceVysledku
n14:7536429
n4:druhVysledku
n17:A
n4:duvernostUdaju
n15:S
n4:entitaPredkladatele
n5:predkladatel
n4:idSjednocenehoVysledku
185446
n4:idVysledku
RIV/15503933:_____/11:#0000016
n4:jazykVysledku
n18:eng
n4:klicovaSlova
InterStand Cooling; Cooling Headers; Final Temperature Control; Heat Transfer Coefficient; Hot Rolling; Hot Strip Mill
n4:klicoveSlovo
n6:Cooling%20Headers n6:Heat%20Transfer%20Coefficient n6:Final%20Temperature%20Control n6:InterStand%20Cooling n6:Hot%20Strip%20Mill n6:Hot%20Rolling
n4:kodPristupu
n7:L
n4:kontrolniKodProRIV
[06C39B247F5C]
n4:mistoVydani
Indianapolis, USA
n4:obor
n13:JP
n4:pocetDomacichTvurcuVysledku
1
n4:pocetTvurcuVysledku
3
n4:projekt
n16:FR-TI1%2F435
n4:rokUplatneniVysledku
n10:2011
n4:tvurceVysledku
Hajduk, Daniel Raudenský, Miroslav Knobloch, Jan