This HTML5 document contains 35 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n12http://localhost/temp/predkladatel/
n13http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n10http://linked.opendata.cz/resource/domain/vavai/subjekt/
n9http://linked.opendata.cz/ontology/domain/vavai/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/
skoshttp://www.w3.org/2004/02/skos/core#
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n16http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216305%3A26310%2F12%3APU99849%21RIV13-MSM-26310___/
n11http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n5http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n15http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n6http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n7http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n14http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216305%3A26310%2F12%3APU99849%21RIV13-MSM-26310___
rdf:type
skos:Concept n9:Vysledek
dcterms:description
In this work, samples produced by chromogenic and special photographic processes as well as inkjet printing techniques were studied in a long-term and accelerated lightfastnesstest.Colour changes of the samples were followed spectrophotometricallyduring both tests. Gamut volumes were calculatedfrom the measured spectra using a custom-programmed utility calledVolGa. Gamut volume change was used as a measure ofsample degradation and was plotted against the corresponding exposure dose. From the regression analysis of the recorded gamut shrinkage data, formal parameters of the fadingrate were determined which can also serve as a tool for the expression of predicted lifetimes. Sample comparison was performed on the basis of 30% gamut volume loss as the suggested endpoint criterion. In this work, samples produced by chromogenic and special photographic processes as well as inkjet printing techniques were studied in a long-term and accelerated lightfastnesstest.Colour changes of the samples were followed spectrophotometricallyduring both tests. Gamut volumes were calculatedfrom the measured spectra using a custom-programmed utility calledVolGa. Gamut volume change was used as a measure ofsample degradation and was plotted against the corresponding exposure dose. From the regression analysis of the recorded gamut shrinkage data, formal parameters of the fadingrate were determined which can also serve as a tool for the expression of predicted lifetimes. Sample comparison was performed on the basis of 30% gamut volume loss as the suggested endpoint criterion.
dcterms:title
Determining The Light-Fastness Of Photographic Output Media Using Gamut Volume Determining The Light-Fastness Of Photographic Output Media Using Gamut Volume
skos:prefLabel
Determining The Light-Fastness Of Photographic Output Media Using Gamut Volume Determining The Light-Fastness Of Photographic Output Media Using Gamut Volume
skos:notation
RIV/00216305:26310/12:PU99849!RIV13-MSM-26310___
n9:predkladatel
n10:orjk%3A26310
n4:aktivita
n15:S
n4:aktivity
S
n4:dodaniDat
n14:2013
n4:domaciTvurceVysledku
n13:5694337 n13:1684892
n4:druhVysledku
n17:O
n4:duvernostUdaju
n5:S
n4:entitaPredkladatele
n16:predkladatel
n4:idSjednocenehoVysledku
130678
n4:idVysledku
RIV/00216305:26310/12:PU99849
n4:jazykVysledku
n6:eng
n4:klicovaSlova
VolGa, colour gamut, lifetime evaluation
n4:klicoveSlovo
n11:VolGa n11:lifetime%20evaluation n11:colour%20gamut
n4:kontrolniKodProRIV
[F7F8D164C213]
n4:obor
n7:CH
n4:pocetDomacichTvurcuVysledku
2
n4:pocetTvurcuVysledku
5
n4:rokUplatneniVysledku
n14:2012
n4:tvurceVysledku
Veselý, Michal Štěpánková, Eva Fürst, Tomáš Dzik, Petr
n12:organizacniJednotka
26310