This HTML5 document contains 41 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n13http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216305%3A26220%2F13%3APU105445%21RIV14-MSM-26220___/
n18http://localhost/temp/predkladatel/
n12http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n10http://linked.opendata.cz/resource/domain/vavai/projekt/
n8http://linked.opendata.cz/resource/domain/vavai/subjekt/
n7http://linked.opendata.cz/ontology/domain/vavai/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n11http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n9http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n17http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n14http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n16http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n15http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n4http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216305%3A26220%2F13%3APU105445%21RIV14-MSM-26220___
rdf:type
n7:Vysledek skos:Concept
dcterms:description
The Cu2O micro/nanoparticles based working electrode was fabricated using the screen-printing method and successfully used for direct electrochemical glucose detection. The linear calibration curve was obtained in the range of concentrations from 0.5 to 10 mmol/L using chronoamperometry method. The Cu2O micro/nanoparticles based working electrode was fabricated using the screen-printing method and successfully used for direct electrochemical glucose detection. The linear calibration curve was obtained in the range of concentrations from 0.5 to 10 mmol/L using chronoamperometry method.
dcterms:title
Direct glucose detection on the Cu2O based screen-printed electrodes Direct glucose detection on the Cu2O based screen-printed electrodes
skos:prefLabel
Direct glucose detection on the Cu2O based screen-printed electrodes Direct glucose detection on the Cu2O based screen-printed electrodes
skos:notation
RIV/00216305:26220/13:PU105445!RIV14-MSM-26220___
n7:predkladatel
n8:orjk%3A26220
n3:aktivita
n17:P
n3:aktivity
P(ED2.1.00/03.0072)
n3:dodaniDat
n4:2014
n3:domaciTvurceVysledku
n12:1661493 n12:5238439 n12:4490916 n12:4489705
n3:druhVysledku
n15:O
n3:duvernostUdaju
n9:S
n3:entitaPredkladatele
n13:predkladatel
n3:idSjednocenehoVysledku
69787
n3:idVysledku
RIV/00216305:26220/13:PU105445
n3:jazykVysledku
n14:eng
n3:klicovaSlova
copper oxide, Cu2O, senzor, glucose, electrochemical detection
n3:klicoveSlovo
n11:Cu2O n11:electrochemical%20detection n11:glucose n11:senzor n11:copper%20oxide
n3:kontrolniKodProRIV
[1226C5FA191F]
n3:obor
n16:CG
n3:pocetDomacichTvurcuVysledku
4
n3:pocetTvurcuVysledku
5
n3:projekt
n10:ED2.1.00%2F03.0072
n3:rokUplatneniVysledku
n4:2013
n3:tvurceVysledku
Prášek, Jan Hubálek, Jaromír Majzlíková, Petra Chomoucká, Jana Trnková, Libuše
n18:organizacniJednotka
26220