This HTML5 document contains 52 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n13http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n19http://purl.org/net/nknouf/ns/bibtex#
n5http://localhost/temp/predkladatel/
n16http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n9http://linked.opendata.cz/resource/domain/vavai/projekt/
n4http://linked.opendata.cz/resource/domain/vavai/subjekt/
n3http://linked.opendata.cz/ontology/domain/vavai/
n12https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n7http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n10http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n22http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n15http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n11http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n20http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n21http://reference.data.gov.uk/id/gregorian-year/
n17http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216305%3A26220%2F12%3APU99884%21RIV14-MSM-26220___/

Statements

Subject Item
n2:RIV%2F00216305%3A26220%2F12%3APU99884%21RIV14-MSM-26220___
rdf:type
skos:Concept n3:Vysledek
dcterms:description
Quartz crystal microbalance belongs to a group of high-sensitive chemical sensors for detection of substances dispersed or dissolved in gas or liquid environments. Several equivalent circuits exist for the QCM sensor. Design of these circuits depends mainly on an active layer of sensor as well as on an environment, in which a sensor is applied. An equivalent circuit is usually separated in two parts; the first one corresponds to quartz crystal, while the second part relates to chemical and physical properties, such as concentration of detected matter, viscosity of an active layer, viscosity of environment, etc.. For design of driven-oscillator circuit of QCM, it is necessary to develop accurate equivalent circuit, which is able to simulate behavior of QCM for a large range of concentration of detected matter. In the paper, the study is provided on polypyrrole-based QCM. Polypyrrole is suitable material for humidity measurements, and was deposited by matrix assisted pulsed laser evaporation technique Quartz crystal microbalance belongs to a group of high-sensitive chemical sensors for detection of substances dispersed or dissolved in gas or liquid environments. Several equivalent circuits exist for the QCM sensor. Design of these circuits depends mainly on an active layer of sensor as well as on an environment, in which a sensor is applied. An equivalent circuit is usually separated in two parts; the first one corresponds to quartz crystal, while the second part relates to chemical and physical properties, such as concentration of detected matter, viscosity of an active layer, viscosity of environment, etc.. For design of driven-oscillator circuit of QCM, it is necessary to develop accurate equivalent circuit, which is able to simulate behavior of QCM for a large range of concentration of detected matter. In the paper, the study is provided on polypyrrole-based QCM. Polypyrrole is suitable material for humidity measurements, and was deposited by matrix assisted pulsed laser evaporation technique
dcterms:title
Equivalent circuit of polypyrrole-based QCM Equivalent circuit of polypyrrole-based QCM
skos:prefLabel
Equivalent circuit of polypyrrole-based QCM Equivalent circuit of polypyrrole-based QCM
skos:notation
RIV/00216305:26220/12:PU99884!RIV14-MSM-26220___
n3:predkladatel
n4:orjk%3A26220
n7:aktivita
n11:S n11:P
n7:aktivity
P(MEB091129), S
n7:dodaniDat
n21:2014
n7:domaciTvurceVysledku
n16:6541763 n16:3455009 n16:3684539 n16:6039618 n16:9770690 n16:1629786
n7:druhVysledku
n18:D
n7:duvernostUdaju
n22:S
n7:entitaPredkladatele
n17:predkladatel
n7:idSjednocenehoVysledku
134645
n7:idVysledku
RIV/00216305:26220/12:PU99884
n7:jazykVysledku
n15:eng
n7:klicovaSlova
gas sesnsing, polypyrrole, humidity, quarzt crystal micorbalance
n7:klicoveSlovo
n10:gas%20sesnsing n10:humidity n10:polypyrrole n10:quarzt%20crystal%20micorbalance
n7:kontrolniKodProRIV
[5FBA21EB90E1]
n7:mistoKonaniAkce
Otočec Slovenia
n7:mistoVydani
Lubljana Slovenia
n7:nazevZdroje
MIDEM Society for Microelectronic, Electronic Components and Materials - Conference 2012 Proceedings
n7:obor
n20:JB
n7:pocetDomacichTvurcuVysledku
6
n7:pocetTvurcuVysledku
6
n7:projekt
n9:MEB091129
n7:rokUplatneniVysledku
n21:2012
n7:tvurceVysledku
Vondra, Marek Holcman, Vladimír Sedlák, Petr Sedláková, Vlasta Šikula, Josef Majzner, Jiří
n7:typAkce
n13:WRD
n7:zahajeniAkce
2012-09-19+02:00
s:numberOfPages
5
n19:hasPublisher
Neuveden
n12:isbn
978-961-92933-2-4
n5:organizacniJednotka
26220