This HTML5 document contains 54 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n16http://localhost/temp/predkladatel/
n13http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n12http://linked.opendata.cz/resource/domain/vavai/projekt/
n14http://linked.opendata.cz/resource/domain/vavai/subjekt/
n10http://linked.opendata.cz/ontology/domain/vavai/
skoshttp://www.w3.org/2004/02/skos/core#
rdfshttp://www.w3.org/2000/01/rdf-schema#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n9http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216305%3A26220%2F12%3APR26150%21RIV13-GA0-26220___/
n6http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n5http://linked.opendata.cz/ontology/domain/vavai/riv/vyuzitiJinymSubjektem/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n8http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n20http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n15http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216305%3A26220%2F12%3APR26150%21RIV13-GA0-26220___
rdf:type
n10:Vysledek skos:Concept
rdfs:seeAlso
http://www.ubmi.feec.vutbr.cz/sites/default/files/products/26150.zip
dcterms:description
Electroencephalography and functional magnetic resonance imaging belong between modalities of brain activity measuring. Several publications with results of joint EEG/fMRI analysis have been realesed in last few years. But none software that would automate calculations has been published. A software EEG Regressor Builder that is preparing regressors from EEG signals was created for this purpose. Regressors are estimated as temporal changes of absolute or relative power values of EEG signals at specific frequency band of interest from selected electrodes of interest. Results are saved into a data structure compatible with freely available software SPM8 (Statistical Parametric Mapping) after the completion of the calculation. SPM8 is used to analyze separate fMRI data. SPM loads results of EEG Regressor Builder and completes the rest of EEG/fMRI analysis together with fMRI data as general linear model estimation. EEG Regressor Builder can calculate the complete EEG/fMRI analysis without running SPM8 software if both are installed on the computer and if path to preprocessed fMRI data on harddisk is added as input parameter. The program can be controlled via a graphical interface or a startup script. Electroencephalography and functional magnetic resonance imaging belong between modalities of brain activity measuring. Several publications with results of joint EEG/fMRI analysis have been realesed in last few years. But none software that would automate calculations has been published. A software EEG Regressor Builder that is preparing regressors from EEG signals was created for this purpose. Regressors are estimated as temporal changes of absolute or relative power values of EEG signals at specific frequency band of interest from selected electrodes of interest. Results are saved into a data structure compatible with freely available software SPM8 (Statistical Parametric Mapping) after the completion of the calculation. SPM8 is used to analyze separate fMRI data. SPM loads results of EEG Regressor Builder and completes the rest of EEG/fMRI analysis together with fMRI data as general linear model estimation. EEG Regressor Builder can calculate the complete EEG/fMRI analysis without running SPM8 software if both are installed on the computer and if path to preprocessed fMRI data on harddisk is added as input parameter. The program can be controlled via a graphical interface or a startup script.
dcterms:title
EEG Regressor Builder EEG Regressor Builder
skos:prefLabel
EEG Regressor Builder EEG Regressor Builder
skos:notation
RIV/00216305:26220/12:PR26150!RIV13-GA0-26220___
n10:predkladatel
n14:orjk%3A26220
n3:aktivita
n4:S n4:P
n3:aktivity
P(GAP304/11/1318), S
n3:dodaniDat
n15:2013
n3:domaciTvurceVysledku
n13:7604688 n13:7927185 n13:3218791
n3:druhVysledku
n20:R
n3:duvernostUdaju
n17:S
n3:ekonomickeParametry
Program je využíván jako pomůcka k vědecko-výzkumné činnosti, v rámci volné licence může tento algoritmus sloužit ke zrychlení procesu společné analýzy EEG-fMRI dat. Software je online dostupný široké vědecké komunitě a může být implementován do libovolného výzkumného softwaru. Jeho vytvoření v programovacím prostředí MATLAB je výhodou, neboť většina ostatních softwarů na trhu (např. SPM8, GIFT, xjview), sloužící k analýze fMRI dat, je vytvořena a vyvíjená také v tomto programovacím prostředí. EEG Regressor Builder je, oproti výše uvedeným softwarům, vyjímečný v tom, že do analýzy fMRI dat automatizovaně přináší informaci z EEG signálů. V současné době je využíván na 1. Neurologické klinice Fakultní nemocnice u Sv. Anny v Brně.
n3:entitaPredkladatele
n9:predkladatel
n3:idSjednocenehoVysledku
132853
n3:idVysledku
RIV/00216305:26220/12:PR26150
n3:interniIdentifikace
EEG Regressor Builder
n3:jazykVysledku
n8:eng
n3:klicovaSlova
EEG signal, electroencephalogram, electroencephalograph, fMRI scan, functional magnetic resonance, oxyhemoglobin, deoxyhemoglobin, hemodynamic response function, MRI tomograph, BOLD signal, blood oxygen level dependent, general linear model, regressor
n3:klicoveSlovo
n6:electroencephalogram n6:fMRI%20scan n6:EEG%20signal n6:blood%20oxygen%20level%20dependent n6:functional%20magnetic%20resonance n6:general%20linear%20model n6:deoxyhemoglobin n6:oxyhemoglobin n6:hemodynamic%20response%20function n6:electroencephalograph n6:MRI%20tomograph n6:regressor n6:BOLD%20signal
n3:kontrolniKodProRIV
[0BA14EBD5278]
n3:obor
n18:JD
n3:pocetDomacichTvurcuVysledku
3
n3:pocetTvurcuVysledku
4
n3:projekt
n12:GAP304%2F11%2F1318
n3:rokUplatneniVysledku
n15:2012
n3:technickeParametry
Program je vytvořen v programovacím jazyku MATLAB. Program je distribuován ve dvou verzích. Jedna slouží pro spouštění ve vezích starších než 7.9.0 (R2009b). Druhá je optimalizováná pro verze 7.9.0 (R2009b) a vyšší. Minimální konfigurace PC: Procesor 2GHz, operační paměť 2GB. Software je volně dostupný na internetu a v současné době je využíván na 1. Neurologické klinice Fakultní nemocnice u Sv. Anny v Brně, která poskytla data použitá při realizaci a testování daného softwaru. Realizace softwaru je výsledkem výzkumného záměru projektu GAP304/11/1318 - Optimalizace metodiky analýzy a hodnocení simultánního EEG-fMRI .
n3:tvurceVysledku
Lamoš, Martin Labounek, René Mareček, Radek Jan, Jiří
n3:vlastnik
n9:vlastnikVysledku
n3:vyuzitiJinymSubjektem
n5:N
n16:organizacniJednotka
26220