This HTML5 document contains 47 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n10http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n11http://localhost/temp/predkladatel/
n9http://purl.org/net/nknouf/ns/bibtex#
n15http://linked.opendata.cz/resource/domain/vavai/projekt/
n14http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n17http://linked.opendata.cz/ontology/domain/vavai/
n16http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216305%3A26220%2F10%3APU91119%21RIV12-MPO-26220___/
n12https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n4http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n7http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n21http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n19http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n5http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n13http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216305%3A26220%2F10%3APU91119%21RIV12-MPO-26220___
rdf:type
skos:Concept n17:Vysledek
dcterms:description
The paper deals with verification of shunting method for limitation of earth fault current in MV compensated networks. The verification was done by experimental measuring which was realized in distribution network held by E.ON Czech Republic. There were made a few different fault (low-impedance, spark gap arc, damaged MV cable, 1.6kOhm, 0.4kOhm and unearthed console of concrete tower) for three different places, for tuned and untuned Petersen coil and for some types of faults for all phases too, that means forty eight experimental faults. During each experiment the shunting of affected phase was applied. The first results of fault currents and voltages analysis show that after closing the shunting circuit breaker the fault current decreases practically to zero that means the method of connecting of affected phase to the earthing system of substation seems be very perspective for protection the point of fault. The paper deals with verification of shunting method for limitation of earth fault current in MV compensated networks. The verification was done by experimental measuring which was realized in distribution network held by E.ON Czech Republic. There were made a few different fault (low-impedance, spark gap arc, damaged MV cable, 1.6kOhm, 0.4kOhm and unearthed console of concrete tower) for three different places, for tuned and untuned Petersen coil and for some types of faults for all phases too, that means forty eight experimental faults. During each experiment the shunting of affected phase was applied. The first results of fault currents and voltages analysis show that after closing the shunting circuit breaker the fault current decreases practically to zero that means the method of connecting of affected phase to the earthing system of substation seems be very perspective for protection the point of fault.
dcterms:title
The verification of shunting method for limitation of earth fault current in MV compensated networks The verification of shunting method for limitation of earth fault current in MV compensated networks
skos:prefLabel
The verification of shunting method for limitation of earth fault current in MV compensated networks The verification of shunting method for limitation of earth fault current in MV compensated networks
skos:notation
RIV/00216305:26220/10:PU91119!RIV12-MPO-26220___
n3:aktivita
n21:P
n3:aktivity
P(2A-2TP1/051)
n3:dodaniDat
n13:2012
n3:domaciTvurceVysledku
n14:3475360 n14:5733804 n14:2446383 n14:3056309 n14:3196380
n3:druhVysledku
n18:D
n3:duvernostUdaju
n7:S
n3:entitaPredkladatele
n16:predkladatel
n3:idSjednocenehoVysledku
295538
n3:idVysledku
RIV/00216305:26220/10:PU91119
n3:jazykVysledku
n19:eng
n3:klicovaSlova
Earth Fault, Shunting Method, Experimental Measuring of the Earth Fault
n3:klicoveSlovo
n4:Earth%20Fault n4:Shunting%20Method n4:Experimental%20Measuring%20of%20the%20Earth%20Fault
n3:kontrolniKodProRIV
[DFBB72368FB6]
n3:mistoKonaniAkce
Buenos Aires, Argentina
n3:mistoVydani
Buenos Aires, Argentina
n3:nazevZdroje
Proceedings of the Congreso Internacional de Distribución Eléctrica
n3:obor
n5:JE
n3:pocetDomacichTvurcuVysledku
5
n3:pocetTvurcuVysledku
5
n3:projekt
n15:2A-2TP1%2F051
n3:rokUplatneniVysledku
n13:2010
n3:tvurceVysledku
Toman, Petr Orságová, Jaroslava Dvořák, Jaromír Blažek, Vladimír Topolánek, David
n3:typAkce
n10:WRD
n3:zahajeniAkce
2010-09-27+02:00
s:numberOfPages
6
n9:hasPublisher
CIDEL
n12:isbn
978-987-97399-3-8
n11:organizacniJednotka
26220