This HTML5 document contains 44 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n11http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n19http://localhost/temp/predkladatel/
n13http://purl.org/net/nknouf/ns/bibtex#
n9http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216305%3A26220%2F10%3APU90176%21RIV14-GA0-26220___/
n15http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n5http://linked.opendata.cz/resource/domain/vavai/projekt/
n21http://linked.opendata.cz/ontology/domain/vavai/
n4https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n12http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n7http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n20http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n14http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n6http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216305%3A26220%2F10%3APU90176%21RIV14-GA0-26220___
rdf:type
skos:Concept n21:Vysledek
dcterms:description
The work deals with n-channel system enabling many sample analysis at sort time from sensor array using electrochemical methods. The system is completely based on standard electronics technology as SMT and screen-printing. The 8x12 sensor arrays is formed from 3-electrodes system created on PCB with combination of galvanic deposition and screen-printing special paste on the electrodes which can be used for heavy metal analysis and also biomolecular complexes and organic toxic substances determination. The control unit switches each 3-electrode sensor to 8-channel precise potentiostat which was designed for electrochemical analysis with current sensitivity below 1 pA. The potentiostat can synchronize with control unit to depress time for analysis to minimum. Developed system is able to measure up to eight single inputs and may be simply converted to measure other values, AV or CV characteristics, transfer functions and nonlinear characteristics for example. Measured data will be sent to user-friendly a The work deals with n-channel system enabling many sample analysis at sort time from sensor array using electrochemical methods. The system is completely based on standard electronics technology as SMT and screen-printing. The 8x12 sensor arrays is formed from 3-electrodes system created on PCB with combination of galvanic deposition and screen-printing special paste on the electrodes which can be used for heavy metal analysis and also biomolecular complexes and organic toxic substances determination. The control unit switches each 3-electrode sensor to 8-channel precise potentiostat which was designed for electrochemical analysis with current sensitivity below 1 pA. The potentiostat can synchronize with control unit to depress time for analysis to minimum. Developed system is able to measure up to eight single inputs and may be simply converted to measure other values, AV or CV characteristics, transfer functions and nonlinear characteristics for example. Measured data will be sent to user-friendly a
dcterms:title
Electronic System for Mass Screening of Toxic Substances in Environment Electronic System for Mass Screening of Toxic Substances in Environment
skos:prefLabel
Electronic System for Mass Screening of Toxic Substances in Environment Electronic System for Mass Screening of Toxic Substances in Environment
skos:notation
RIV/00216305:26220/10:PU90176!RIV14-GA0-26220___
n3:aktivita
n14:P
n3:aktivity
P(GA102/08/1546), P(GA102/09/1601), P(KAN208130801)
n3:dodaniDat
n6:2014
n3:domaciTvurceVysledku
n15:8777543 n15:4489705
n3:druhVysledku
n18:D
n3:duvernostUdaju
n7:S
n3:entitaPredkladatele
n9:predkladatel
n3:idSjednocenehoVysledku
256791
n3:idVysledku
RIV/00216305:26220/10:PU90176
n3:jazykVysledku
n20:eng
n3:klicovaSlova
potentiostat, electrochemical analysis, mass screening, sensor array
n3:klicoveSlovo
n12:sensor%20array n12:electrochemical%20analysis n12:potentiostat n12:mass%20screening
n3:kontrolniKodProRIV
[07247AE52F9E]
n3:mistoKonaniAkce
Warsaw
n3:mistoVydani
Warsaw
n3:nazevZdroje
IEEE Xplore Digital Library, Electronics technology (ISSE), 2010: 33rd International Spring Seminar on Electronics Technology
n3:obor
n17:JB
n3:pocetDomacichTvurcuVysledku
2
n3:pocetTvurcuVysledku
3
n3:projekt
n5:KAN208130801 n5:GA102%2F09%2F1601 n5:GA102%2F08%2F1546
n3:rokUplatneniVysledku
n6:2010
n3:tvurceVysledku
Hubálek, Jaromír Žák, Jaromír
n3:typAkce
n11:EUR
n3:zahajeniAkce
2010-05-12+02:00
s:numberOfPages
5
n13:hasPublisher
Neuveden
n4:isbn
978-1-4244-7850-7
n19:organizacniJednotka
26220