This HTML5 document contains 41 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n11http://localhost/temp/predkladatel/
n12http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n17http://linked.opendata.cz/ontology/domain/vavai/
n13http://linked.opendata.cz/resource/domain/vavai/zamer/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n4http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n6http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n8http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n14http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n16http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216305%3A26220%2F08%3APU78896%21RIV10-MSM-26220___/
n9http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n15http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n5http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216305%3A26220%2F08%3APU78896%21RIV10-MSM-26220___
rdf:type
n17:Vysledek skos:Concept
dcterms:description
A facility for testing the performance of hydrogen safety sensors under a wide range of ambient conditions is described. A specific test protocol was developed to test sensors under conditions which could reasonably be expected during the sensors service life. The tests were based on those described in IEC 61779 and were adapted following consultation with car manufacturers and after careful consideration of the sensors expected service environmental conditions. The protocol was evaluated by using it to test a large number of commercially available sensors. Observations made and experience gained during the testing campaign allowed the test protocol to be fine-tuned bearing in mind the sensor performance and behaviour during tests. The result of this work is an experimentally evaluated methodology which may be used as a guideline for testing the suitability of hydrogen sensors for automotive applications. 2008 International Association for Hydrogen Energy. Published by Elsevier Ltd. All rights reserve A facility for testing the performance of hydrogen safety sensors under a wide range of ambient conditions is described. A specific test protocol was developed to test sensors under conditions which could reasonably be expected during the sensors service life. The tests were based on those described in IEC 61779 and were adapted following consultation with car manufacturers and after careful consideration of the sensors expected service environmental conditions. The protocol was evaluated by using it to test a large number of commercially available sensors. Observations made and experience gained during the testing campaign allowed the test protocol to be fine-tuned bearing in mind the sensor performance and behaviour during tests. The result of this work is an experimentally evaluated methodology which may be used as a guideline for testing the suitability of hydrogen sensors for automotive applications. 2008 International Association for Hydrogen Energy. Published by Elsevier Ltd. All rights reserve
dcterms:title
Reliability of commercially available hydrogen sensors for detection of hydrogen at critical concentrations: Part I Testing facility and methodologies Reliability of commercially available hydrogen sensors for detection of hydrogen at critical concentrations: Part I Testing facility and methodologies
skos:prefLabel
Reliability of commercially available hydrogen sensors for detection of hydrogen at critical concentrations: Part I Testing facility and methodologies Reliability of commercially available hydrogen sensors for detection of hydrogen at critical concentrations: Part I Testing facility and methodologies
skos:notation
RIV/00216305:26220/08:PU78896!RIV10-MSM-26220___
n4:aktivita
n9:Z
n4:aktivity
Z(MSM0021630503)
n4:cisloPeriodika
1
n4:dodaniDat
n5:2010
n4:domaciTvurceVysledku
n12:6824927 n12:8845263
n4:druhVysledku
n15:J
n4:duvernostUdaju
n8:S
n4:entitaPredkladatele
n16:predkladatel
n4:idSjednocenehoVysledku
392248
n4:idVysledku
RIV/00216305:26220/08:PU78896
n4:jazykVysledku
n14:eng
n4:klicovaSlova
Hydrogen sensor, Hydrogen detection, Safety, Test facility, Performance evaluation
n4:klicoveSlovo
n6:Safety n6:Hydrogen%20detection n6:Hydrogen%20sensor n6:Performance%20evaluation n6:Test%20facility
n4:kodStatuVydavatele
GB - Spojené království Velké Británie a Severního Irska
n4:kontrolniKodProRIV
[5DD2FF1A6B4D]
n4:nazevZdroje
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY
n4:obor
n18:JA
n4:pocetDomacichTvurcuVysledku
2
n4:pocetTvurcuVysledku
2
n4:rokUplatneniVysledku
n5:2008
n4:svazekPeriodika
2008
n4:tvurceVysledku
Boušek, Jaroslav Salyk, Ota
n4:zamer
n13:MSM0021630503
s:issn
0360-3199
s:numberOfPages
10
n11:organizacniJednotka
26220