This HTML5 document contains 43 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n5http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n16http://localhost/temp/predkladatel/
n11http://purl.org/net/nknouf/ns/bibtex#
n12http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n15http://linked.opendata.cz/ontology/domain/vavai/
n19https://schema.org/
n17http://linked.opendata.cz/resource/domain/vavai/zamer/
n18http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216305%3A26220%2F08%3APU78671%21RIV10-MSM-26220___/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n4http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n21http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n20http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n9http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n7http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n14http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216305%3A26220%2F08%3APU78671%21RIV10-MSM-26220___
rdf:type
n15:Vysledek skos:Concept
dcterms:description
The compensated networks are affected by the phase capacity asymmetry of wiring, which causes the unbalancing of the phase voltages in the tuned condition of the arc-suppression coil. In the especially unfavourable cases this effect reduces the possibility of network operation with the tuned arc-suppression coil. The operation with the arc-suppression coil out of tune is accompanied by higher values of the fault currents during the ground faults and the natural frequency of the course of recovery voltage in the network after switching off or interrupting the ground fault. These disadvantages can only be removed by efficient elimination of the phase asymmetry. The new methods of eliminating the phase capacity asymmetry allow for controlling the phase asymmetry size (its reduction as well as its possible increase), they keep it within a specified tolerance band (Uo value in the tuned condition of the arc-suppression coil is typically maintained at levels from 1% to 4% of the network voltage phase value) The compensated networks are affected by the phase capacity asymmetry of wiring, which causes the unbalancing of the phase voltages in the tuned condition of the arc-suppression coil. In the especially unfavourable cases this effect reduces the possibility of network operation with the tuned arc-suppression coil. The operation with the arc-suppression coil out of tune is accompanied by higher values of the fault currents during the ground faults and the natural frequency of the course of recovery voltage in the network after switching off or interrupting the ground fault. These disadvantages can only be removed by efficient elimination of the phase asymmetry. The new methods of eliminating the phase capacity asymmetry allow for controlling the phase asymmetry size (its reduction as well as its possible increase), they keep it within a specified tolerance band (Uo value in the tuned condition of the arc-suppression coil is typically maintained at levels from 1% to 4% of the network voltage phase value)
dcterms:title
Solution of Voltage Asymmetry and Reduction of Outage Time in MV Compensated Networks Solution of Voltage Asymmetry and Reduction of Outage Time in MV Compensated Networks
skos:prefLabel
Solution of Voltage Asymmetry and Reduction of Outage Time in MV Compensated Networks Solution of Voltage Asymmetry and Reduction of Outage Time in MV Compensated Networks
skos:notation
RIV/00216305:26220/08:PU78671!RIV10-MSM-26220___
n3:aktivita
n20:Z
n3:aktivity
Z(MSM0021630516)
n3:dodaniDat
n14:2010
n3:domaciTvurceVysledku
n12:5733804 n12:3475360 n12:4433440
n3:druhVysledku
n10:D
n3:duvernostUdaju
n21:S
n3:entitaPredkladatele
n18:predkladatel
n3:idSjednocenehoVysledku
395838
n3:idVysledku
RIV/00216305:26220/08:PU78671
n3:jazykVysledku
n9:eng
n3:klicovaSlova
voltage asymmetry, outage time reduction
n3:klicoveSlovo
n4:voltage%20asymmetry n4:outage%20time%20reduction
n3:kontrolniKodProRIV
[5F6B5603719D]
n3:mistoKonaniAkce
Wollongong
n3:mistoVydani
Neuveden
n3:nazevZdroje
Proceedings of the 13th International Conference on Harmonics and Quality of Power
n3:obor
n7:JE
n3:pocetDomacichTvurcuVysledku
3
n3:pocetTvurcuVysledku
3
n3:rokUplatneniVysledku
n14:2008
n3:tvurceVysledku
Toman, Petr Orságová, Jaroslava Drápela, Jiří
n3:typAkce
n5:WRD
n3:wos
000262985500078
n3:zahajeniAkce
2008-09-28+02:00
n3:zamer
n17:MSM0021630516
s:numberOfPages
7
n11:hasPublisher
Neuveden
n19:isbn
978-1-4244-1770-4
n16:organizacniJednotka
26220