This HTML5 document contains 48 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n19http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n21http://purl.org/net/nknouf/ns/bibtex#
n15http://localhost/temp/predkladatel/
n8http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n4http://linked.opendata.cz/ontology/domain/vavai/
n20http://linked.opendata.cz/resource/domain/vavai/zamer/
n12https://schema.org/
shttp://schema.org/
n6http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216305%3A26220%2F07%3APU72147%21RIV08-MSM-26220___/
skoshttp://www.w3.org/2004/02/skos/core#
n5http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n14http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n7http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n18http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n11http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n16http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n9http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216305%3A26220%2F07%3APU72147%21RIV08-MSM-26220___
rdf:type
n4:Vysledek skos:Concept
dcterms:description
The paper presents analytic design of active magnetic bearing PM synchronous motor for TAH (Total Artificial Heart) application and description of the drive and levitation electromagnet control. Pump system is double ventricle blood pump consisting of slotless PM axial flux synchronous machine and magnetic active bearings. The general electric machine theory is applied to the motor design. Power quality is ensured by the help of the rare earth PM and for good torque quality is used slotless, three phase winding and surface mounting PM. Control part deals with the synchronous motor and magnetic bearing control. Two structures, voltage and current, were design and tested for the position regulation. Mathematical model was successfully simulated. On the base of this model the regulation structure for positional feedback control was design. Design of the regulators is based on the mathematical model description of controlled system. The paper presents analytic design of active magnetic bearing PM synchronous motor for TAH (Total Artificial Heart) application and description of the drive and levitation electromagnet control. Pump system is double ventricle blood pump consisting of slotless PM axial flux synchronous machine and magnetic active bearings. The general electric machine theory is applied to the motor design. Power quality is ensured by the help of the rare earth PM and for good torque quality is used slotless, three phase winding and surface mounting PM. Control part deals with the synchronous motor and magnetic bearing control. Two structures, voltage and current, were design and tested for the position regulation. Mathematical model was successfully simulated. On the base of this model the regulation structure for positional feedback control was design. Design of the regulators is based on the mathematical model description of controlled system. The paper presents analytic design of active magnetic bearing PM synchronous motor for TAH (Total Artificial Heart) application and description of the drive and levitation electromagnet control. Pump system is double ventricle blood pump consisting of slotless PM axial flux synchronous machine and magnetic active bearings. The general electric machine theory is applied to the motor design. Power quality is ensured by the help of the rare earth PM and for good torque quality is used slotless, three phase winding and surface mounting PM. Control part deals with the synchronous motor and magnetic bearing control. Two structures, voltage and current, were design and tested for the position regulation. Mathematical model was successfully simulated. On the base of this model the regulation structure for positional feedback control was design. Design of the regulators is based on the mathematical model description of controlled system.
dcterms:title
DRIVE AND CONTROL SYSTEM FOR TAH APPLICATION DRIVE AND CONTROL SYSTEM FOR TAH APPLICATION DRIVE AND CONTROL SYSTEM FOR TAH APPLICATION
skos:prefLabel
DRIVE AND CONTROL SYSTEM FOR TAH APPLICATION DRIVE AND CONTROL SYSTEM FOR TAH APPLICATION DRIVE AND CONTROL SYSTEM FOR TAH APPLICATION
skos:notation
RIV/00216305:26220/07:PU72147!RIV08-MSM-26220___
n5:strany
179-184
n5:aktivita
n11:Z
n5:aktivity
Z(MSM0021630518)
n5:dodaniDat
n9:2008
n5:domaciTvurceVysledku
n8:1022512 n8:7031904 n8:4915585
n5:druhVysledku
n17:D
n5:duvernostUdaju
n7:S
n5:entitaPredkladatele
n6:predkladatel
n5:idSjednocenehoVysledku
418147
n5:idVysledku
RIV/00216305:26220/07:PU72147
n5:jazykVysledku
n18:eng
n5:klicovaSlova
magnetic bearing, SMPM, artificial heart, control structure
n5:klicoveSlovo
n14:control%20structure n14:magnetic%20bearing n14:artificial%20heart n14:SMPM
n5:kontrolniKodProRIV
[C053E0CD6E58]
n5:mistoKonaniAkce
Liberec
n5:mistoVydani
Liberec
n5:nazevZdroje
Sborník konference Liberecké pohony LIPO2007
n5:obor
n16:JA
n5:pocetDomacichTvurcuVysledku
3
n5:pocetTvurcuVysledku
3
n5:rokUplatneniVysledku
n9:2007
n5:tvurceVysledku
Huták, Petr Pazdera, Ivo Láníček, Tomáš
n5:typAkce
n19:CST
n5:zahajeniAkce
2007-11-06+01:00
n5:zamer
n20:MSM0021630518
s:numberOfPages
6
n21:hasPublisher
TU Liberec
n12:isbn
978-80-7372-272-2
n15:organizacniJednotka
26220