This HTML5 document contains 49 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n11http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n19http://purl.org/net/nknouf/ns/bibtex#
n5http://localhost/temp/predkladatel/
n17http://linked.opendata.cz/resource/domain/vavai/projekt/
n14http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n18http://linked.opendata.cz/ontology/domain/vavai/
n20http://linked.opendata.cz/resource/domain/vavai/zamer/
n16https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n4http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n15http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n13http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n21http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n7http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216305%3A26220%2F07%3APU68367%21RIV08-GA0-26220___/
n22http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n8http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n6http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216305%3A26220%2F07%3APU68367%21RIV08-GA0-26220___
rdf:type
n18:Vysledek skos:Concept
dcterms:description
Tento článek popisuje real-time implementaci řídicího algoritmu ze simulačního prostředí do programovatelného automatu (PLC). Při vývoji řídicího algoritmu by měl být reálný systém spojený se simulačním prostředím pomocí PLC aby bylo možné řídicí algoritmus otestovat přímo na reálném systému. V tomto případě slouží PLC pouze jako vstupně-výstupní zařízení a všechny výpočty probíhají pouze v simulačním prostředí - MATLAB/Simulinku. K tomuto spojení slouží process visualization interface, které komunikuje pomocí různých komunikačních protokolů: Ethernet, RS232, CAN or ProfiBus. All implementation steps are shown on one of advanced control algorithms - the Generalized Predictive Control. This paper shows real-time implementation of control algorithms from a simulation environment into the Programmable Logic Controller (PLC). Development of control algorithms is necessary for their use in a simulation environment and verification on simulation models. The real control system should be connected to the simulation environment with a PLC to test the control algorithms on a real physical model. In this case the PLC is used only as an IO device and all computations are performed in the simulation environment - MATLAB/Simulink. This connection is ensured via a general process visualization interface, which can transmit a data via different communication protocols: Ethernet, RS232, CAN or ProfiBus. Finally, the control algorithm should be implemented into the PLC and MATLAB/Simulink can be used for monitoring of the process input, output or others parameters. All implementation steps are shown on one of advanced control algorithms - the Generalized Predictive Control. This paper shows real-time implementation of control algorithms from a simulation environment into the Programmable Logic Controller (PLC). Development of control algorithms is necessary for their use in a simulation environment and verification on simulation models. The real control system should be connected to the simulation environment with a PLC to test the control algorithms on a real physical model. In this case the PLC is used only as an IO device and all computations are performed in the simulation environment - MATLAB/Simulink. This connection is ensured via a general process visualization interface, which can transmit a data via different communication protocols: Ethernet, RS232, CAN or ProfiBus. Finally, the control algorithm should be implemented into the PLC and MATLAB/Simulink can be used for monitoring of the process input, output or others parameters. All implementation steps are shown on one of advanced control algorithms - the Generalized Predictive Control.
dcterms:title
Real-Time Communication between MATLAB/Simulink and PLC via Process Visualization Interface Real-Time Communication between MATLAB/Simulink and PLC via Process Visualization Interface Real-Time komunikace mezi MATLAB/Simulinkem a PLC pomocí Process Visualization Interface
skos:prefLabel
Real-Time Communication between MATLAB/Simulink and PLC via Process Visualization Interface Real-Time Communication between MATLAB/Simulink and PLC via Process Visualization Interface Real-Time komunikace mezi MATLAB/Simulinkem a PLC pomocí Process Visualization Interface
skos:notation
RIV/00216305:26220/07:PU68367!RIV08-GA0-26220___
n3:strany
28-32
n3:aktivita
n13:Z n13:P
n3:aktivity
P(GA102/06/1132), Z(MSM0021630529)
n3:dodaniDat
n6:2008
n3:domaciTvurceVysledku
n14:9304010 n14:7849508
n3:druhVysledku
n22:D
n3:duvernostUdaju
n15:S
n3:entitaPredkladatele
n7:predkladatel
n3:idSjednocenehoVysledku
446585
n3:idVysledku
RIV/00216305:26220/07:PU68367
n3:jazykVysledku
n21:eng
n3:klicovaSlova
PLC, Real-Time, MATLAB, Simulink, Predictive Control
n3:klicoveSlovo
n4:MATLAB n4:Simulink n4:PLC n4:Real-Time n4:Predictive%20Control
n3:kontrolniKodProRIV
[CB1E22CB99E9]
n3:mistoKonaniAkce
Crete
n3:mistoVydani
Neuveden
n3:nazevZdroje
VOLUME 2 of the Proceedings of the 11th WSEAS International Multiconference CSCC
n3:obor
n8:BC
n3:pocetDomacichTvurcuVysledku
2
n3:pocetTvurcuVysledku
2
n3:projekt
n17:GA102%2F06%2F1132
n3:rokUplatneniVysledku
n6:2007
n3:tvurceVysledku
Mikšánek, Vojtěch Pivoňka, Petr
n3:typAkce
n11:WRD
n3:zahajeniAkce
2007-07-23+02:00
n3:zamer
n20:MSM0021630529
s:numberOfPages
5
n19:hasPublisher
Neuveden
n16:isbn
978-960-8457-90-4
n5:organizacniJednotka
26220