This HTML5 document contains 48 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n16http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n18http://purl.org/net/nknouf/ns/bibtex#
n21http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216305%3A26220%2F05%3APU51305%21RIV08-GA0-26220___/
n14http://localhost/temp/predkladatel/
n10http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n5http://linked.opendata.cz/resource/domain/vavai/projekt/
n17http://linked.opendata.cz/ontology/domain/vavai/
n20https://schema.org/
n15http://linked.opendata.cz/resource/domain/vavai/zamer/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n4http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n19http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n12http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n9http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n22http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n13http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n8http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216305%3A26220%2F05%3APU51305%21RIV08-GA0-26220___
rdf:type
skos:Concept n17:Vysledek
dcterms:description
In various sphere of industry like in medicine, in agriculture, in food-processing industry or in living environment is needed to recognize matters of analyte. Analyte is the matter we determine. To determining a matter in scaned solution we use sensors. A sensors made by thick film technology are the substrate for production of biosensors. Biosensor is analytical instrument containing sensitive element biological origin, which is part of it or in tight contact with physical-chemical convertor. It provides running electronical signal, which is commensurable to concentration one or some (group) of chemical matters in a sample. Acquired signal for next processing reach very small value of current or voltage. Measured current from microelectrodes reach values from pA to mA. Whole system is optimized for measuring these small values of magnitudes. For measuring is used method of cyclic voltammetry, where is analyzed current response on triangle input voltage. Current response is logarithmic so there is a In various sphere of industry like in medicine, in agriculture, in food-processing industry or in living environment is needed to recognize matters of analyte. Analyte is the matter we determine. To determining a matter in scaned solution we use sensors. A sensors made by thick film technology are the substrate for production of biosensors. Biosensor is analytical instrument containing sensitive element biological origin, which is part of it or in tight contact with physical-chemical convertor. It provides running electronical signal, which is commensurable to concentration one or some (group) of chemical matters in a sample. Acquired signal for next processing reach very small value of current or voltage. Measured current from microelectrodes reach values from pA to mA. Whole system is optimized for measuring these small values of magnitudes. For measuring is used method of cyclic voltammetry, where is analyzed current response on triangle input voltage. Current response is logarithmic so there is a In various sphere of industry like in medicine, in agriculture, in food-processing industry or in living environment is needed to recognize matters of analyte. Analyte is the matter we determine. To determining a matter in scaned solution we use sensors. A sensors made by thick film technology are the substrate for production of biosensors. Biosensor is analytical instrument containing sensitive element biological origin, which is part of it or in tight contact with physical-chemical convertor. It provides running electronical signal, which is commensurable to concentration one or some (group) of chemical matters in a sample. Acquired signal for next processing reach very small value of current or voltage. Measured current from microelectrodes reach values from pA to mA. Whole system is optimized for measuring these small values of magnitudes. For measuring is used method of cyclic voltammetry, where is analyzed current response on triangle input voltage. Current response is logarithmic so there is a
dcterms:title
Potenciostat s velkým proudovým rozsahem Wide Current Range Potentiostat Wide Current Range Potentiostat
skos:prefLabel
Wide Current Range Potentiostat Potenciostat s velkým proudovým rozsahem Wide Current Range Potentiostat
skos:notation
RIV/00216305:26220/05:PU51305!RIV08-GA0-26220___
n3:strany
21-24
n3:aktivita
n9:P n9:Z
n3:aktivity
P(FD-K2/53), P(GA102/03/0619), Z(MSM0021630503)
n3:dodaniDat
n8:2008
n3:domaciTvurceVysledku
n10:8379920 n10:6824927
n3:druhVysledku
n13:D
n3:duvernostUdaju
n19:S
n3:entitaPredkladatele
n21:predkladatel
n3:idSjednocenehoVysledku
551429
n3:idVysledku
RIV/00216305:26220/05:PU51305
n3:jazykVysledku
n12:eng
n3:klicovaSlova
potentiostat, cyclic voltammetry, PC interface,
n3:klicoveSlovo
n4:potentiostat n4:PC%20interface n4:cyclic%20voltammetry
n3:kontrolniKodProRIV
[E9B818C64059]
n3:mistoKonaniAkce
Brno
n3:mistoVydani
Brno
n3:nazevZdroje
EDS '05 IMAPS CS International Conference Proceedings
n3:obor
n22:JA
n3:pocetDomacichTvurcuVysledku
2
n3:pocetTvurcuVysledku
2
n3:projekt
n5:GA102%2F03%2F0619 n5:FD-K2%2F53
n3:rokUplatneniVysledku
n8:2005
n3:tvurceVysledku
Havlíček, Tomáš Boušek, Jaroslav
n3:typAkce
n16:CST
n3:zahajeniAkce
2005-09-15+02:00
n3:zamer
n15:MSM0021630503
s:numberOfPages
4
n18:hasPublisher
Vysoké učení technické v Brně
n20:isbn
80-214-2990-9
n14:organizacniJednotka
26220