This HTML5 document contains 52 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n18http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n20http://purl.org/net/nknouf/ns/bibtex#
n7http://localhost/temp/predkladatel/
n12http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n6http://linked.opendata.cz/resource/domain/vavai/projekt/
n19http://linked.opendata.cz/ontology/domain/vavai/
n8http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216305%3A26220%2F03%3APU36423%21RIV06-GA0-26220___/
n5http://linked.opendata.cz/resource/domain/vavai/zamer/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n14http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n13http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n15http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n21http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n16http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216305%3A26220%2F03%3APU36423%21RIV06-GA0-26220___
rdf:type
skos:Concept n19:Vysledek
dcterms:description
Environmental scanning electron microscopy (ESEM) or low-vacuum scanning electron microscopy (LV SEM) enables the visualisation of samples in a gaseous environment at the pressure of the specimen chamber from 1 Pa to over 1000 Pa. Detection of signal electrons, namely secondary electrons (SE) cannot be realised in a gaseous environment of the specimen chamber in the same way as for the high vacuum SEM, because high voltage of the Everhart-Thornley detector is not compatible with the conductance of the llow vacuum environment [1]. For this reason, gaseous ions which are ionised by SE from the specimen are used for the detection in ESEM. For the detection of the backscattered electrons (BSES), conventional scintillation detector is the best to use. Environmentální rastrovací elektronový mikroskop (EREM), nebo nízkovakuový rastrovací elektronový mikroskop (LV REM) dovolují pozorovat vzorky v prostředí plynu při tlacích od 1Pa až do tlaku kolem 1000Pa. Detekce signálových elektronů v EREM, zejména sekundárních elektronů (SE), nemůže být realizována stejným způsobem jako je tomu v SEM, protože vysoké napětí Everhart-Thornley detektoru by v prostředí vysokého tlaku způsobovalů výboje či průrazy v plynu. Environmental scanning electron microscopy (ESEM) or low-vacuum scanning electron microscopy (LV SEM) enables the visualisation of samples in a gaseous environment at the pressure of the specimen chamber from 1 Pa to over 1000 Pa. Detection of signal electrons, namely secondary electrons (SE) cannot be realised in a gaseous environment of the specimen chamber in the same way as for the high vacuum SEM, because high voltage of the Everhart-Thornley detector is not compatible with the conductance of the llow vacuum environment [1]. For this reason, gaseous ions which are ionised by SE from the specimen are used for the detection in ESEM. For the detection of the backscattered electrons (BSES), conventional scintillation detector is the best to use.
dcterms:title
Comparison of imaging with SE ionisation and BSE scintillation detector in ESEM Comparison of imaging with SE ionisation and BSE scintillation detector in ESEM Srovnání obrazu získaného pomocí ionizačního SE detektoru a scintilačního BSE detektoru v EREM.
skos:prefLabel
Comparison of imaging with SE ionisation and BSE scintillation detector in ESEM Comparison of imaging with SE ionisation and BSE scintillation detector in ESEM Srovnání obrazu získaného pomocí ionizačního SE detektoru a scintilačního BSE detektoru v EREM.
skos:notation
RIV/00216305:26220/03:PU36423!RIV06-GA0-26220___
n3:strany
487-488
n3:aktivita
n15:Z n15:P
n3:aktivity
P(GA102/01/1271), P(GA102/05/0886), Z(MSM 262200010)
n3:dodaniDat
n16:2006
n3:domaciTvurceVysledku
n12:2608944 n12:1783017
n3:druhVysledku
n21:D
n3:duvernostUdaju
n13:S
n3:entitaPredkladatele
n8:predkladatel
n3:idSjednocenehoVysledku
601729
n3:idVysledku
RIV/00216305:26220/03:PU36423
n3:jazykVysledku
n4:eng
n3:klicovaSlova
Comparison, SE, ionisation, BSE, scintillation, ESEM
n3:klicoveSlovo
n14:Comparison n14:ESEM n14:SE n14:BSE n14:ionisation n14:scintillation
n3:kontrolniKodProRIV
[807AD13E3D6B]
n3:mistoKonaniAkce
Pula
n3:mistoVydani
Pula
n3:nazevZdroje
Proceedings 6th Multinational Congress on Microscopy
n3:obor
n10:JA
n3:pocetDomacichTvurcuVysledku
2
n3:pocetTvurcuVysledku
4
n3:projekt
n6:GA102%2F05%2F0886 n6:GA102%2F01%2F1271
n3:rokUplatneniVysledku
n16:2003
n3:tvurceVysledku
Horký, Drahomír Autrata, Rudolf Neděla, Vilém Schauer, Petr
n3:typAkce
n18:WRD
n3:zahajeniAkce
2003-06-01+02:00
n3:zamer
n5:MSM%20262200010
s:numberOfPages
2
n20:hasPublisher
Neuveden
n7:organizacniJednotka
26220