This HTML5 document contains 40 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n7http://localhost/temp/predkladatel/
n8http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n6http://linked.opendata.cz/resource/domain/vavai/projekt/
n16http://linked.opendata.cz/ontology/domain/vavai/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n15http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216305%3A26210%2F14%3APU111219%21RIV15-MSM-26210___/
n5http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n11http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n14http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n13http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n9http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216305%3A26210%2F14%3APU111219%21RIV15-MSM-26210___
rdf:type
skos:Concept n16:Vysledek
dcterms:description
The paper presents research on heat transfer coefficient at the surface of sprinkled tube bundle with boil simulation. A tube bundle comprises of thirteen copper tubes divided into two rows and it is located in a low-pressure chamber where vacuum is generated using an exhauster via ejector. The liquid tested was water at absolute pressure in a chamber in between 96.8 kPa up until 12.3 kPa and a thermal gradient 55 to 30 degC between the cooled liquid flowing inside the exchanger upwards and the falling film heated liquid. The flow of the falling film liquid ranged from zero to 17 litres per minute. Two types of tubes have been tested, a smooth one and a sandblasted one. The correlation of average heat transfer coefficient at the surface of both tube types has been created. The paper presents research on heat transfer coefficient at the surface of sprinkled tube bundle with boil simulation. A tube bundle comprises of thirteen copper tubes divided into two rows and it is located in a low-pressure chamber where vacuum is generated using an exhauster via ejector. The liquid tested was water at absolute pressure in a chamber in between 96.8 kPa up until 12.3 kPa and a thermal gradient 55 to 30 degC between the cooled liquid flowing inside the exchanger upwards and the falling film heated liquid. The flow of the falling film liquid ranged from zero to 17 litres per minute. Two types of tubes have been tested, a smooth one and a sandblasted one. The correlation of average heat transfer coefficient at the surface of both tube types has been created.
dcterms:title
Correlation of Heat Transfer Coefficient at Sprinkled Tube Bundle Correlation of Heat Transfer Coefficient at Sprinkled Tube Bundle
skos:prefLabel
Correlation of Heat Transfer Coefficient at Sprinkled Tube Bundle Correlation of Heat Transfer Coefficient at Sprinkled Tube Bundle
skos:notation
RIV/00216305:26210/14:PU111219!RIV15-MSM-26210___
n3:aktivita
n12:P
n3:aktivity
P(LO1202)
n3:dodaniDat
n9:2015
n3:domaciTvurceVysledku
n8:9423869 n8:7248032 n8:3191664 n8:6900755 n8:6273432
n3:druhVysledku
n17:O
n3:duvernostUdaju
n11:S
n3:entitaPredkladatele
n15:predkladatel
n3:idSjednocenehoVysledku
9006
n3:idVysledku
RIV/00216305:26210/14:PU111219
n3:jazykVysledku
n14:eng
n3:klicovaSlova
sprinkled, water, under pressure, heat transfer
n3:klicoveSlovo
n5:under%20pressure n5:water n5:sprinkled n5:heat%20transfer
n3:kontrolniKodProRIV
[323338E81859]
n3:obor
n13:JE
n3:pocetDomacichTvurcuVysledku
5
n3:pocetTvurcuVysledku
5
n3:projekt
n6:LO1202
n3:rokUplatneniVysledku
n9:2014
n3:tvurceVysledku
Baláš, Marek Šnajdárek, Ladislav Lisý, Martin Pospíšil, Jiří Kracík, Petr
n7:organizacniJednotka
26210