This HTML5 document contains 48 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n17http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n12http://localhost/temp/predkladatel/
n10http://purl.org/net/nknouf/ns/bibtex#
n11http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n4http://linked.opendata.cz/resource/domain/vavai/projekt/
n21http://linked.opendata.cz/resource/domain/vavai/subjekt/
n8http://linked.opendata.cz/ontology/domain/vavai/
n9https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n6http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n15http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n18http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216305%3A26210%2F12%3APU98859%21RIV13-MSM-26210___/
n19http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n7http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n22http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n20http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n5http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216305%3A26210%2F12%3APU98859%21RIV13-MSM-26210___
rdf:type
n8:Vysledek skos:Concept
dcterms:description
The purpose of this study is to describe the effect of slide-to-roll ratio on the film formation and thickness in artificial CoCrMo metal femoral head and a glass disc contact lubricated with Bovine Serum. The experiment is carried out using an optical testing device and high speed camera capturing chromatic interferograms of the contact zone. The interferograms are evaluated using thin film colorimetric interferometry. The resulting film formation and thickness is studied as a function of time for three different slide-to-roll ratio values. Rolling showed formation of steadily increasing film up to thickness of 23 nm. The sliding test with ball faster than disc did not result in a significant film formation, only a thin film of 2 to 4 nm was formed. The other sliding test with disc faster than ball developed thinner base film of 4 to 20 nm and a thicker protein aggregation film of 60 to 120 nm. The purpose of this study is to describe the effect of slide-to-roll ratio on the film formation and thickness in artificial CoCrMo metal femoral head and a glass disc contact lubricated with Bovine Serum. The experiment is carried out using an optical testing device and high speed camera capturing chromatic interferograms of the contact zone. The interferograms are evaluated using thin film colorimetric interferometry. The resulting film formation and thickness is studied as a function of time for three different slide-to-roll ratio values. Rolling showed formation of steadily increasing film up to thickness of 23 nm. The sliding test with ball faster than disc did not result in a significant film formation, only a thin film of 2 to 4 nm was formed. The other sliding test with disc faster than ball developed thinner base film of 4 to 20 nm and a thicker protein aggregation film of 60 to 120 nm.
dcterms:title
Effect of Slide-to-roll Ratio on Film Thickness Formation in Bovine Serum Lubricated Contact Effect of Slide-to-roll Ratio on Film Thickness Formation in Bovine Serum Lubricated Contact
skos:prefLabel
Effect of Slide-to-roll Ratio on Film Thickness Formation in Bovine Serum Lubricated Contact Effect of Slide-to-roll Ratio on Film Thickness Formation in Bovine Serum Lubricated Contact
skos:notation
RIV/00216305:26210/12:PU98859!RIV13-MSM-26210___
n8:predkladatel
n21:orjk%3A26210
n3:aktivita
n7:P
n3:aktivity
P(ED0002/01/01)
n3:dodaniDat
n5:2013
n3:domaciTvurceVysledku
n11:4867033 n11:4455282 n11:4167481 n11:2948400
n3:druhVysledku
n22:D
n3:duvernostUdaju
n15:S
n3:entitaPredkladatele
n18:predkladatel
n3:idSjednocenehoVysledku
133259
n3:idVysledku
RIV/00216305:26210/12:PU98859
n3:jazykVysledku
n19:eng
n3:klicovaSlova
Artificial hip joint, Biotribology, Bovine serum, Metal femoral head
n3:klicoveSlovo
n6:Biotribology n6:Artificial%20hip%20joint n6:Bovine%20serum n6:Metal%20femoral%20head
n3:kontrolniKodProRIV
[6CD8E9EF6B9A]
n3:mistoKonaniAkce
Tábor
n3:mistoVydani
Praha
n3:nazevZdroje
Proceedings of the 50th Anuual Conference on Experimental Stress Analysis
n3:obor
n20:BO
n3:pocetDomacichTvurcuVysledku
4
n3:pocetTvurcuVysledku
4
n3:projekt
n4:ED0002%2F01%2F01
n3:rokUplatneniVysledku
n5:2012
n3:tvurceVysledku
Bosák, Dalibor Návrat, Tomáš Vrbka, Martin Laštůvka, Jan
n3:typAkce
n17:EUR
n3:wos
000314083900037
n3:zahajeniAkce
2012-06-04+02:00
s:numberOfPages
6
n10:hasPublisher
České vysoké učení technické v Praze
n9:isbn
978-80-01-05060-6
n12:organizacniJednotka
26210