This HTML5 document contains 41 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n7http://localhost/temp/predkladatel/
n9http://linked.opendata.cz/resource/domain/vavai/projekt/
n6http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n13http://linked.opendata.cz/resource/domain/vavai/subjekt/
n12http://linked.opendata.cz/ontology/domain/vavai/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/
skoshttp://www.w3.org/2004/02/skos/core#
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n15http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216305%3A26210%2F12%3APU101654%21RIV13-MSM-26210___/
n5http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n11http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n18http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n14http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n16http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n8http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216305%3A26210%2F12%3APU101654%21RIV13-MSM-26210___
rdf:type
skos:Concept n12:Vysledek
dcterms:description
A special interaction chamber was designed to be compatible with the New Wave UP MACRO Laser Ablation System and to fulfill all demands for simultaneous measurements double pulse laser-induced breakdown spectroscopy (DP-LIBS) and laser ablation coupled to ICP optical emission or mass spectrometry. For single pulse LIBS only two orthogonal fused silica windows are used, the first from the top for the ablation laser beam and the second one from the front for collecting the light of plasma. For DP-LIBS the third window from the side is needed being orthogonal to the previous two. For Laser ablation ICP OES/MS a flow of transporting gas has to be implemented. The inner space of the chamber was optimized for low volume and quick flush of gas, which is crucial for the method. The gas enters the chamber through three oblique jets on the top and leaves to the ICP on the back side. The chamber is equipped with a vertically adjustable sample holder to adapt various sample heights and exchangeable inner rings al A special interaction chamber was designed to be compatible with the New Wave UP MACRO Laser Ablation System and to fulfill all demands for simultaneous measurements double pulse laser-induced breakdown spectroscopy (DP-LIBS) and laser ablation coupled to ICP optical emission or mass spectrometry. For single pulse LIBS only two orthogonal fused silica windows are used, the first from the top for the ablation laser beam and the second one from the front for collecting the light of plasma. For DP-LIBS the third window from the side is needed being orthogonal to the previous two. For Laser ablation ICP OES/MS a flow of transporting gas has to be implemented. The inner space of the chamber was optimized for low volume and quick flush of gas, which is crucial for the method. The gas enters the chamber through three oblique jets on the top and leaves to the ICP on the back side. The chamber is equipped with a vertically adjustable sample holder to adapt various sample heights and exchangeable inner rings al
dcterms:title
Ablation Chamber for Simultaneous DP-LIBS and Laser Ablation ICP-OES/MS Ablation Chamber for Simultaneous DP-LIBS and Laser Ablation ICP-OES/MS
skos:prefLabel
Ablation Chamber for Simultaneous DP-LIBS and Laser Ablation ICP-OES/MS Ablation Chamber for Simultaneous DP-LIBS and Laser Ablation ICP-OES/MS
skos:notation
RIV/00216305:26210/12:PU101654!RIV13-MSM-26210___
n12:predkladatel
n13:orjk%3A26210
n4:aktivita
n14:P
n4:aktivity
P(ED1.1.00/02.0068), P(ME08002), P(ME09015)
n4:dodaniDat
n8:2013
n4:domaciTvurceVysledku
n6:6620477 n6:4788303 n6:9001840 n6:2393646
n4:druhVysledku
n17:O
n4:duvernostUdaju
n11:S
n4:entitaPredkladatele
n15:predkladatel
n4:idSjednocenehoVysledku
120762
n4:idVysledku
RIV/00216305:26210/12:PU101654
n4:jazykVysledku
n18:eng
n4:klicovaSlova
DP-LIBS, Laser ablation, ICP-OES/MS, ablation chamber
n4:klicoveSlovo
n5:Laser%20ablation n5:DP-LIBS n5:ablation%20chamber n5:ICP-OES%2FMS
n4:kontrolniKodProRIV
[23334EE1E07C]
n4:obor
n16:BL
n4:pocetDomacichTvurcuVysledku
4
n4:pocetTvurcuVysledku
7
n4:projekt
n9:ME09015 n9:ME08002 n9:ED1.1.00%2F02.0068
n4:rokUplatneniVysledku
n8:2012
n4:tvurceVysledku
Malina, Radomír Novotný, Karel Kaiser, Jozef Hrdlička, Aleš
n7:organizacniJednotka
26210