This HTML5 document contains 52 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n19http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n23http://localhost/temp/predkladatel/
n16http://purl.org/net/nknouf/ns/bibtex#
n21http://linked.opendata.cz/resource/domain/vavai/projekt/
n13http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n17http://linked.opendata.cz/resource/domain/vavai/subjekt/
n8http://linked.opendata.cz/ontology/domain/vavai/
n18https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
rdfshttp://www.w3.org/2000/01/rdf-schema#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n7http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216305%3A26210%2F12%3APU101563%21RIV13-GA0-26210___/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n4http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n14http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n20http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n9http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n11http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216305%3A26210%2F12%3APU101563%21RIV13-GA0-26210___
rdf:type
n8:Vysledek skos:Concept
rdfs:seeAlso
http://www.atdsr.sk
dcterms:description
Článek navazuje na loňský příspěvek, s názvem Thermo diagnostika využití pro sledování pracovního prostředí parametrů. Operativní teplota, respektive střední radiační teplota, odráží kvalitu vnitřního prostředí podstatně lépe než teplota vzduchu, popřípadě teplota v kombinaci s vlhkostí. Tento článek se zabývá možnostmi měření střední radiační teploty a operativní teploty, a pak i dosažitelnou přesností. Článek navazuje na loňský příspěvek, s názvem Thermo diagnostika využití pro sledování pracovního prostředí parametrů. Operativní teplota, respektive střední radiační teplota, odráží kvalitu vnitřního prostředí podstatně lépe než teplota vzduchu, popřípadě teplota v kombinaci s vlhkostí. Tento článek se zabývá možnostmi měření střední radiační teploty a operativní teploty, a pak i dosažitelnou přesností. Article builds on last year's contribution, titled Thermo diagnostics use for monitoring of the working environment parameters. The operative temperature, respectively mean radiant temperature, reflects the quality of the indoor environment significantly better than the air temperature, eventually in combination with humidity. This paper deals with the possibilities of measurement of mean radiant temperature and operative temperature, and then also over the achievable accuracy.
dcterms:title
Monitoring the mean radiant temperature and operative temperature as parameters of the working environment Sledovanie strednej radiačnej teploty a operativne teploty ako parametrov pracovného prostredia Sledovanie strednej radiačnej teploty a operativne teploty ako parametrov pracovného prostredia
skos:prefLabel
Monitoring the mean radiant temperature and operative temperature as parameters of the working environment Sledovanie strednej radiačnej teploty a operativne teploty ako parametrov pracovného prostredia Sledovanie strednej radiačnej teploty a operativne teploty ako parametrov pracovného prostredia
skos:notation
RIV/00216305:26210/12:PU101563!RIV13-GA0-26210___
n8:predkladatel
n17:orjk%3A26210
n3:aktivita
n10:P
n3:aktivity
P(GD101/09/H050)
n3:dodaniDat
n11:2013
n3:domaciTvurceVysledku
n13:1996266 n13:7861680 n13:5601657
n3:druhVysledku
n20:D
n3:duvernostUdaju
n12:S
n3:entitaPredkladatele
n7:predkladatel
n3:idSjednocenehoVysledku
168438
n3:idVysledku
RIV/00216305:26210/12:PU101563
n3:jazykVysledku
n14:cze
n3:klicovaSlova
Thermal comfort, environmental monitoring, mean radiant temperature, operative temperature, compact sensor of operative temperature, test chamber, calibration chamber
n3:klicoveSlovo
n4:operative%20temperature n4:mean%20radiant%20temperature n4:Thermal%20comfort n4:test%20chamber n4:calibration%20chamber n4:compact%20sensor%20of%20operative%20temperature n4:environmental%20monitoring
n3:kontrolniKodProRIV
[A448138DE723]
n3:mistoKonaniAkce
Košice
n3:mistoVydani
Košice
n3:nazevZdroje
Teória a aplikácia metód technickej diagnostiky 2012
n3:obor
n9:JB
n3:pocetDomacichTvurcuVysledku
3
n3:pocetTvurcuVysledku
3
n3:projekt
n21:GD101%2F09%2FH050
n3:rokUplatneniVysledku
n11:2012
n3:tvurceVysledku
Košíková, Jana Janečka, Jan Vdoleček, František
n3:typAkce
n19:EUR
n3:zahajeniAkce
2012-10-02+02:00
s:numberOfPages
8
n16:hasPublisher
ATD SR + TU Košice FS
n18:isbn
978-80-553-1088-6
n23:organizacniJednotka
26210