This HTML5 document contains 38 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n8http://localhost/temp/predkladatel/
n14http://linked.opendata.cz/resource/domain/vavai/projekt/
n17http://linked.opendata.cz/resource/domain/vavai/subjekt/
n12http://linked.opendata.cz/ontology/domain/vavai/
skoshttp://www.w3.org/2004/02/skos/core#
rdfshttp://www.w3.org/2000/01/rdf-schema#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n5http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216305%3A26210%2F11%3APU96437%21RIV12-MPO-26210___/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n6http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n13http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n16http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n15http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n7http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216305%3A26210%2F11%3APU96437%21RIV12-MPO-26210___
rdf:type
n12:Vysledek skos:Concept
rdfs:seeAlso
http://quench.forschung.kit.edu/
dcterms:description
Severe accident mitigation measures are gradually implemented at Slovak nuclear power plants. Coolant injection, into primary circuit and depressurization system of primary circuit were included within the scope of measures to cope with severe accidents. One of the crucial issues of these systems is to ensure successful quenching of the core during water delivery in severe accident conditions. System is designed to deliver water into primary circuit, spent fuel pool and also to containment spray system. Water delivery into primary circuit, capable of quenching the core, has to be considered in connection with design of the primary circuit depressurization system for severe accident conditions in order to maintain such low pressure in primary circuit that is necessary to keep required water flow into primary circuit. Conservative approach was used for design of both (depressurization system and system for water delivery into primary circuit), but best estimate analyses were executed to prove their inte Severe accident mitigation measures are gradually implemented at Slovak nuclear power plants. Coolant injection, into primary circuit and depressurization system of primary circuit were included within the scope of measures to cope with severe accidents. One of the crucial issues of these systems is to ensure successful quenching of the core during water delivery in severe accident conditions. System is designed to deliver water into primary circuit, spent fuel pool and also to containment spray system. Water delivery into primary circuit, capable of quenching the core, has to be considered in connection with design of the primary circuit depressurization system for severe accident conditions in order to maintain such low pressure in primary circuit that is necessary to keep required water flow into primary circuit. Conservative approach was used for design of both (depressurization system and system for water delivery into primary circuit), but best estimate analyses were executed to prove their inte
dcterms:title
Assessment of the design of injection and depressurization system dedicated for severe accidents for VVER440 Assessment of the design of injection and depressurization system dedicated for severe accidents for VVER440
skos:prefLabel
Assessment of the design of injection and depressurization system dedicated for severe accidents for VVER440 Assessment of the design of injection and depressurization system dedicated for severe accidents for VVER440
skos:notation
RIV/00216305:26210/11:PU96437!RIV12-MPO-26210___
n12:predkladatel
n17:orjk%3A26210
n3:aktivita
n13:P
n3:aktivity
P(2A-1TP1/067)
n3:dodaniDat
n7:2012
n3:domaciTvurceVysledku
Baláž, Jozef
n3:druhVysledku
n15:O
n3:duvernostUdaju
n18:S
n3:entitaPredkladatele
n5:predkladatel
n3:idSjednocenehoVysledku
187293
n3:idVysledku
RIV/00216305:26210/11:PU96437
n3:jazykVysledku
n4:eng
n3:klicovaSlova
Depressurization, Hydrogen production, Quenching, Cladding, Primary circuit, Reactor Pressure Vessel, Core
n3:klicoveSlovo
n6:Reactor%20Pressure%20Vessel n6:Primary%20circuit n6:Hydrogen%20production n6:Cladding n6:Core n6:Quenching n6:Depressurization
n3:kontrolniKodProRIV
[EB2B0FCD4BC5]
n3:obor
n16:JF
n3:pocetDomacichTvurcuVysledku
1
n3:pocetTvurcuVysledku
2
n3:projekt
n14:2A-1TP1%2F067
n3:rokUplatneniVysledku
n7:2011
n3:tvurceVysledku
Jančovič, Juraj Baláž, Jozef
n8:organizacniJednotka
26210