This HTML5 document contains 42 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n17http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
n21http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216305%3A26210%2F08%3APU76965%21RIV10-MSM-26210___/
dctermshttp://purl.org/dc/terms/
n16http://purl.org/net/nknouf/ns/bibtex#
n13http://localhost/temp/predkladatel/
n11http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n7http://linked.opendata.cz/ontology/domain/vavai/
n18http://linked.opendata.cz/resource/domain/vavai/zamer/
n9https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n4http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n14http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n20http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n19http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n6http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n5http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216305%3A26210%2F08%3APU76965%21RIV10-MSM-26210___
rdf:type
n7:Vysledek skos:Concept
dcterms:description
The paper deals with the problems of ceramic head of hip joint endoprosthesis destructions in vivo, and with assessing the impact of shape deflections of conical surfaces on the tensile stress in the head. There are assumed two material characteristics of the stem - the first is linear elastic and the second is bilinear plastic modelled austenitic steel used in the bio-implants. Concerned are shape deviations from the ideal conical surfaces of the stem and the head of the endoprosthesis. The shape deviations may be modelled at the macro-level - this concerns model shape inaccuracies such as deviation from the nominal degree of taper, at the micro-level - when the stochastic distribution of unevenness on the contact areas is respected. The problem of stress in ceramic heads was solved using the algorithm of the finite element method - system ANSYS under ISO 7206-5 loading. In the paper are presented and analysed the results of solution of the macro-level shape deviations and micro-level shape deviation The paper deals with the problems of ceramic head of hip joint endoprosthesis destructions in vivo, and with assessing the impact of shape deflections of conical surfaces on the tensile stress in the head. There are assumed two material characteristics of the stem - the first is linear elastic and the second is bilinear plastic modelled austenitic steel used in the bio-implants. Concerned are shape deviations from the ideal conical surfaces of the stem and the head of the endoprosthesis. The shape deviations may be modelled at the macro-level - this concerns model shape inaccuracies such as deviation from the nominal degree of taper, at the micro-level - when the stochastic distribution of unevenness on the contact areas is respected. The problem of stress in ceramic heads was solved using the algorithm of the finite element method - system ANSYS under ISO 7206-5 loading. In the paper are presented and analysed the results of solution of the macro-level shape deviations and micro-level shape deviation
dcterms:title
Stress Analysis of the Ceramics Head with Micro and Macro Shape Deviations of the Contact Areas Stress Analysis of the Ceramics Head with Micro and Macro Shape Deviations of the Contact Areas
skos:prefLabel
Stress Analysis of the Ceramics Head with Micro and Macro Shape Deviations of the Contact Areas Stress Analysis of the Ceramics Head with Micro and Macro Shape Deviations of the Contact Areas
skos:notation
RIV/00216305:26210/08:PU76965!RIV10-MSM-26210___
n4:aktivita
n10:S n10:Z
n4:aktivity
S, Z(AV0Z20760514)
n4:dodaniDat
n5:2010
n4:domaciTvurceVysledku
n11:8834091 n11:4751833
n4:druhVysledku
n6:D
n4:duvernostUdaju
n12:S
n4:entitaPredkladatele
n21:predkladatel
n4:idSjednocenehoVysledku
397685
n4:idVysledku
RIV/00216305:26210/08:PU76965
n4:jazykVysledku
n20:eng
n4:klicovaSlova
Biomechanics, hip joint endorporsthesis, shape deviations
n4:klicoveSlovo
n14:Biomechanics n14:shape%20deviations n14:hip%20joint%20endorporsthesis
n4:kontrolniKodProRIV
[FEE26C5B3DE1]
n4:mistoKonaniAkce
Praha
n4:mistoVydani
Praha
n4:nazevZdroje
Human biomechanics 2008
n4:obor
n19:BO
n4:pocetDomacichTvurcuVysledku
2
n4:pocetTvurcuVysledku
2
n4:rokUplatneniVysledku
n5:2008
n4:tvurceVysledku
Hlavoň, Pavel Fuis, Vladimír
n4:typAkce
n17:WRD
n4:zahajeniAkce
2008-09-29+02:00
n4:zamer
n18:AV0Z20760514
s:numberOfPages
2
n16:hasPublisher
Neuveden
n9:isbn
978-80-01-04163-5
n13:organizacniJednotka
26210