This HTML5 document contains 44 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n19http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n13http://localhost/temp/predkladatel/
n4http://purl.org/net/nknouf/ns/bibtex#
n8http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n15http://linked.opendata.cz/ontology/domain/vavai/
n20http://linked.opendata.cz/resource/domain/vavai/zamer/
n7https://schema.org/
n18http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216305%3A26210%2F08%3APU74692%21RIV10-MSM-26210___/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n12http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n16http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n17http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n6http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n14http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n5http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n10http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216305%3A26210%2F08%3APU74692%21RIV10-MSM-26210___
rdf:type
n15:Vysledek skos:Concept
dcterms:description
The article focuses on the effect of transpedicular cemented and non-cemented screws applied in osteoporotic vertebrae and on the stability of connection between the bone and screw when subjected to extraction test. Cemented and non-cemented screws were inserted in experimental vertebral samples and extracted using a standard testing device. The obtained results prove that the extraction force in cemented screws is significantly higher than in non-cemented screws (t-test, p value = 0.007). The article focuses on the effect of transpedicular cemented and non-cemented screws applied in osteoporotic vertebrae and on the stability of connection between the bone and screw when subjected to extraction test. Cemented and non-cemented screws were inserted in experimental vertebral samples and extracted using a standard testing device. The obtained results prove that the extraction force in cemented screws is significantly higher than in non-cemented screws (t-test, p value = 0.007).
dcterms:title
COMPARATIVE ANALYSIS OF SOCON CS SCREWS IN TREATMENT OF OSTEOPOROTIC VERTEBRAL FRACTURES COMPARATIVE ANALYSIS OF SOCON CS SCREWS IN TREATMENT OF OSTEOPOROTIC VERTEBRAL FRACTURES
skos:prefLabel
COMPARATIVE ANALYSIS OF SOCON CS SCREWS IN TREATMENT OF OSTEOPOROTIC VERTEBRAL FRACTURES COMPARATIVE ANALYSIS OF SOCON CS SCREWS IN TREATMENT OF OSTEOPOROTIC VERTEBRAL FRACTURES
skos:notation
RIV/00216305:26210/08:PU74692!RIV10-MSM-26210___
n3:aktivita
n17:Z
n3:aktivity
Z(MSM0021630518)
n3:dodaniDat
n10:2010
n3:domaciTvurceVysledku
n8:5559073 n8:2948400 n8:6497950
n3:druhVysledku
n5:D
n3:duvernostUdaju
n16:S
n3:entitaPredkladatele
n18:predkladatel
n3:idSjednocenehoVysledku
360496
n3:idVysledku
RIV/00216305:26210/08:PU74692
n3:jazykVysledku
n6:eng
n3:klicovaSlova
transpedicular cemented and non-cemented screws, osteoporotic vertebrae
n3:klicoveSlovo
n12:osteoporotic%20vertebrae n12:transpedicular%20cemented%20and%20non-cemented%20screws
n3:kontrolniKodProRIV
[B542409A9DE5]
n3:mistoKonaniAkce
Wisla
n3:mistoVydani
Gliwice
n3:nazevZdroje
Modelling and Optimization of Physical Systems
n3:obor
n14:BO
n3:pocetDomacichTvurcuVysledku
3
n3:pocetTvurcuVysledku
5
n3:rokUplatneniVysledku
n10:2008
n3:tvurceVysledku
Návrat, Tomáš Houfek, Lubomír Černohousová, Iva Kočiš, Ján Florian, Zdeněk
n3:typAkce
n19:EUR
n3:zahajeniAkce
2008-06-13+02:00
n3:zamer
n20:MSM0021630518
s:numberOfPages
4
n4:hasPublisher
Wydawnictvo Katedry Mechaniki Stosowanej
n7:isbn
978-83-60102-50-3
n13:organizacniJednotka
26210