This HTML5 document contains 46 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n3http://localhost/temp/predkladatel/
n13http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n11http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216305%3A26110%2F13%3APU106815%21RIV14-MSM-26110___/
n18http://linked.opendata.cz/resource/domain/vavai/subjekt/
n12http://linked.opendata.cz/ontology/domain/vavai/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n4http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n5http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n8http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n17http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n15http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n16http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n6http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n10http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216305%3A26110%2F13%3APU106815%21RIV14-MSM-26110___
rdf:type
n12:Vysledek skos:Concept
dcterms:description
In accordance with standard CSN 73 0540 - Thermal protection of buildings, individual structures must show increasingly lower values of heat transfer coefficient U [W/m2K]. When dealing with structure details, due to stricter thermal and technical requirements, it is necessary to eliminate the occurrence of less clear thermal bridges. This can be reached not only by suitable structural changes, but also by the development of new construction materials. In accordance with standard CSN 73 0540 - Thermal protection of buildings, individual structures must show increasingly lower values of heat transfer coefficient U [W/m2K]. When dealing with structure details, due to stricter thermal and technical requirements, it is necessary to eliminate the occurrence of less clear thermal bridges. This can be reached not only by suitable structural changes, but also by the development of new construction materials.
dcterms:title
Impact of Outer Wall Insulation Method at the Reinforced Concrete Strip Footing on the Temperature Factor and Linear Heat Transfer Coefficient Impact of Outer Wall Insulation Method at the Reinforced Concrete Strip Footing on the Temperature Factor and Linear Heat Transfer Coefficient
skos:prefLabel
Impact of Outer Wall Insulation Method at the Reinforced Concrete Strip Footing on the Temperature Factor and Linear Heat Transfer Coefficient Impact of Outer Wall Insulation Method at the Reinforced Concrete Strip Footing on the Temperature Factor and Linear Heat Transfer Coefficient
skos:notation
RIV/00216305:26110/13:PU106815!RIV14-MSM-26110___
n12:predkladatel
n18:orjk%3A26110
n4:aktivita
n15:S
n4:aktivity
S
n4:cisloPeriodika
2
n4:dodaniDat
n10:2014
n4:domaciTvurceVysledku
n13:1346296 n13:1518933 n13:6614094 n13:3623106 n13:1007769
n4:druhVysledku
n16:J
n4:duvernostUdaju
n8:S
n4:entitaPredkladatele
n11:predkladatel
n4:idSjednocenehoVysledku
79018
n4:idVysledku
RIV/00216305:26110/13:PU106815
n4:jazykVysledku
n17:eng
n4:klicovaSlova
thermal insulation, composite material, recycled material, steady state, linear thermal transmittance
n4:klicoveSlovo
n5:recycled%20material n5:linear%20thermal%20transmittance n5:composite%20material n5:steady%20state n5:thermal%20insulation
n4:kodStatuVydavatele
IN - Indická republika
n4:kontrolniKodProRIV
[75B185AFD581]
n4:nazevZdroje
International Journal of Civil and Environmental Engineering
n4:obor
n6:JN
n4:pocetDomacichTvurcuVysledku
5
n4:pocetTvurcuVysledku
5
n4:rokUplatneniVysledku
n10:2013
n4:svazekPeriodika
35
n4:tvurceVysledku
Matějka, Libor Pěnčík, Jan Kalužová, Alena Pospíšil, Tomáš
s:issn
1701-8285
s:numberOfPages
6
n3:organizacniJednotka
26110