This HTML5 document contains 42 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n13http://localhost/temp/predkladatel/
n18http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n12http://linked.opendata.cz/resource/domain/vavai/projekt/
n6http://linked.opendata.cz/resource/domain/vavai/subjekt/
n5http://linked.opendata.cz/ontology/domain/vavai/
n10http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216305%3A26110%2F13%3APU103781%21RIV14-GA0-26110___/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n8http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n11http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n19http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n14http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n15http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n4http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216305%3A26110%2F13%3APU103781%21RIV14-GA0-26110___
rdf:type
n5:Vysledek skos:Concept
dcterms:description
When examining brickwork, also ultrasonic pulse method is used to determinate the material properties such as strength, modulus of elasticity, and so on. In general terms, test results are influenced by many factors such as length of measuring base, probe frequency, specimen dimensions, moisture, and internal structure or its defects, and the like. Bricks built in masonry can show various moisture and structure values, but also defects related to manufacturing technology which are acceptable in the light of use nevertheless, they influence test results when testing the bricks by ultrasonic pulse method. Analysis of findings concerning the influence of moisture and brick sounding technique implies that test results are influenced in varying degrees. The highest reproducibility ratio is shown in case of calcium silicate bricks and the lowest one occurs with extruded clay bricks. Here, synergic action of moisture, state of structure (porosity), and clinker defects are manifested. To interpret correctly t When examining brickwork, also ultrasonic pulse method is used to determinate the material properties such as strength, modulus of elasticity, and so on. In general terms, test results are influenced by many factors such as length of measuring base, probe frequency, specimen dimensions, moisture, and internal structure or its defects, and the like. Bricks built in masonry can show various moisture and structure values, but also defects related to manufacturing technology which are acceptable in the light of use nevertheless, they influence test results when testing the bricks by ultrasonic pulse method. Analysis of findings concerning the influence of moisture and brick sounding technique implies that test results are influenced in varying degrees. The highest reproducibility ratio is shown in case of calcium silicate bricks and the lowest one occurs with extruded clay bricks. Here, synergic action of moisture, state of structure (porosity), and clinker defects are manifested. To interpret correctly t
dcterms:title
Bricks built in Masonry: Influence of Sounding Techniques and Moisture on Ultrasonic Pulse Transmission Velocity During Parameter Determination Bricks built in Masonry: Influence of Sounding Techniques and Moisture on Ultrasonic Pulse Transmission Velocity During Parameter Determination
skos:prefLabel
Bricks built in Masonry: Influence of Sounding Techniques and Moisture on Ultrasonic Pulse Transmission Velocity During Parameter Determination Bricks built in Masonry: Influence of Sounding Techniques and Moisture on Ultrasonic Pulse Transmission Velocity During Parameter Determination
skos:notation
RIV/00216305:26110/13:PU103781!RIV14-GA0-26110___
n5:predkladatel
n6:orjk%3A26110
n3:aktivita
n19:P
n3:aktivity
P(ED2.1.00/03.0097), P(GAP104/12/0810)
n3:cisloPeriodika
5
n3:dodaniDat
n4:2014
n3:domaciTvurceVysledku
n18:7709706
n3:druhVysledku
n15:J
n3:duvernostUdaju
n11:S
n3:entitaPredkladatele
n10:predkladatel
n3:idSjednocenehoVysledku
63867
n3:idVysledku
RIV/00216305:26110/13:PU103781
n3:jazykVysledku
n14:eng
n3:klicovaSlova
Ultrasonic pulse method, Clay brick, Silicate brick, Ultrasonic pulse velocity, Transmission, Moisture
n3:klicoveSlovo
n8:Ultrasonic%20pulse%20velocity n8:Transmission n8:Ultrasonic%20pulse%20method n8:Silicate%20brick n8:Moisture n8:Clay%20brick
n3:kodStatuVydavatele
AT - Rakouská republika
n3:kontrolniKodProRIV
[A1FCE35BC727]
n3:nazevZdroje
WULFENIA
n3:obor
n17:JN
n3:pocetDomacichTvurcuVysledku
1
n3:pocetTvurcuVysledku
1
n3:projekt
n12:GAP104%2F12%2F0810 n12:ED2.1.00%2F03.0097
n3:rokUplatneniVysledku
n4:2013
n3:svazekPeriodika
20
n3:tvurceVysledku
Brožovský, Jiří
s:issn
1561-882X
s:numberOfPages
10
n13:organizacniJednotka
26110