This HTML5 document contains 45 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n17http://linked.opendata.cz/ontology/domain/vavai/riv/typAkce/
dctermshttp://purl.org/dc/terms/
n18http://purl.org/net/nknouf/ns/bibtex#
n7http://localhost/temp/predkladatel/
n12http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n14http://linked.opendata.cz/resource/domain/vavai/subjekt/
n13http://linked.opendata.cz/ontology/domain/vavai/
n8https://schema.org/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n4http://linked.opendata.cz/ontology/domain/vavai/riv/
n16http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216275%3A25510%2F13%3A39896888%21RIV14-MSM-25510___/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n11http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n6http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n15http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n5http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n21http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n19http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n10http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216275%3A25510%2F13%3A39896888%21RIV14-MSM-25510___
rdf:type
skos:Concept n13:Vysledek
dcterms:description
Tento příspěvek se zabývá simulačními a experimentálními pracemi ověřujícími vliv rekuperujících vozidel na trakční usměrňovač s proraženými diodami v napájecích stanicích (3kV DC) české železnice. Nedílnou součástí práce je ověření vlivu rekuperujících vozidel na trakční transformátor. Analýzy jsou provedeny pomocí počítačových simulací napájecí stanice a měření průběhů na laboratorním transformátoru s dvojicí sekundárních vinutí zapojených do D a do Y. Tento příspěvek se zabývá simulačními a experimentálními pracemi ověřujícími vliv rekuperujících vozidel na trakční usměrňovač s proraženými diodami v napájecích stanicích (3kV DC) české železnice. Nedílnou součástí práce je ověření vlivu rekuperujících vozidel na trakční transformátor. Analýzy jsou provedeny pomocí počítačových simulací napájecí stanice a měření průběhů na laboratorním transformátoru s dvojicí sekundárních vinutí zapojených do D a do Y. The paper deals with the fault states of twelve-pulse rectifier in traction substation of 3 kV DC traction system used at railways in the Czech Republic. The situation at diode breakdown of rectifier and at the same time recuperative traction vehicles in power supply section. The vehicle with recuperation can increase stress of elements in power supply system under certain conditions during fault states of rectifier. The simulation computer model was created for analysis of current waveforms in trolley line at this situation. The all simulations were done by program PSpice. The main goal is to analyze the endanger elements of power supply system and bring the recommendation for increasing of reliability of this mentioned power supply system.
dcterms:title
The effect of fault states of the twelve-pulse rectifier during the recuperation Vliv průrazu diod v napájecí stanici na rekuperující vozidla soustavy 3kV DC Vliv průrazu diod v napájecí stanici na rekuperující vozidla soustavy 3kV DC
skos:prefLabel
Vliv průrazu diod v napájecí stanici na rekuperující vozidla soustavy 3kV DC Vliv průrazu diod v napájecí stanici na rekuperující vozidla soustavy 3kV DC The effect of fault states of the twelve-pulse rectifier during the recuperation
skos:notation
RIV/00216275:25510/13:39896888!RIV14-MSM-25510___
n13:predkladatel
n14:orjk%3A25510
n4:aktivita
n15:S
n4:aktivity
S
n4:dodaniDat
n10:2014
n4:domaciTvurceVysledku
n12:9820078
n4:druhVysledku
n21:D
n4:duvernostUdaju
n6:S
n4:entitaPredkladatele
n16:predkladatel
n4:idSjednocenehoVysledku
114663
n4:idVysledku
RIV/00216275:25510/13:39896888
n4:jazykVysledku
n5:cze
n4:klicovaSlova
transformer; traction substation; recuperation; diode breakdown; Twelve-pulse rectifier; component
n4:klicoveSlovo
n11:traction%20substation n11:recuperation n11:diode%20breakdown n11:component n11:transformer n11:Twelve-pulse%20rectifier
n4:kontrolniKodProRIV
[AA4E4C1759E4]
n4:mistoKonaniAkce
Pardubice
n4:mistoVydani
Pardubice
n4:nazevZdroje
Sborník z konference Elektrotechnická zařízení v dopravě 2013
n4:obor
n19:JE
n4:pocetDomacichTvurcuVysledku
1
n4:pocetTvurcuVysledku
1
n4:rokUplatneniVysledku
n10:2013
n4:tvurceVysledku
Mlynařík, Ladislav
n4:typAkce
n17:CST
n4:zahajeniAkce
2013-02-28+01:00
s:numberOfPages
12
n18:hasPublisher
Univerzita Pardubice
n8:isbn
978-80-7395-575-5
n7:organizacniJednotka
25510