This HTML5 document contains 57 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n11http://localhost/temp/predkladatel/
n5http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n4http://linked.opendata.cz/ontology/domain/vavai/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n17http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216275%3A25310%2F14%3A39898595%21RIV15-MSM-25310___/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n7http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n6http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n15http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n16http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n14http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n9http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216275%3A25310%2F14%3A39898595%21RIV15-MSM-25310___
rdf:type
n4:Vysledek skos:Concept
dcterms:description
Two types of plastic bonded explosives (PBXs) based on e-2,4,6,8,10,12-hexanitro-2,4,6,8,10,12-hexaazaisowurtzitane (e-HNIW, CL-20), and PBXs based on 1,3,5-trinitro-1,3,5-triazinane (RDX), b-1,3,4,7-tetranitro-1,3,5,7-tetrazocane (b-HMX) and cis-1,3,4,6-tetranitro-octahydroimidazo-[4,5-d]imidazole (bicyclo-HMX, BCHMX) were prepd. using a polyisobutylene binder, i.e. a C4 matrix. One version of the e-HNIW PBX is a product with reduced sensitivity (RS-e-HNIW). All these PBXs were tested using the Small Scale Gap Test according to STANAG 4488. The results on the PBXs with RDX, b-HMX and BCHMX correspond to the impact sensitivities of the original cryst. nitramines. This is not entirely valid for e-HNIW. In other words, PBXs with RS-e-HNIW cannot achieve as low a shock sensitivity as would be expected from the differences obtained from the impact sensitivities between RDX, b-HMX and BCHMX, on the one hand, and RS-e-HNIW on the other. It is shown that the morphological stability of RS-e-HNIW in the C4 matrix is insufficient. Two types of plastic bonded explosives (PBXs) based on e-2,4,6,8,10,12-hexanitro-2,4,6,8,10,12-hexaazaisowurtzitane (e-HNIW, CL-20), and PBXs based on 1,3,5-trinitro-1,3,5-triazinane (RDX), b-1,3,4,7-tetranitro-1,3,5,7-tetrazocane (b-HMX) and cis-1,3,4,6-tetranitro-octahydroimidazo-[4,5-d]imidazole (bicyclo-HMX, BCHMX) were prepd. using a polyisobutylene binder, i.e. a C4 matrix. One version of the e-HNIW PBX is a product with reduced sensitivity (RS-e-HNIW). All these PBXs were tested using the Small Scale Gap Test according to STANAG 4488. The results on the PBXs with RDX, b-HMX and BCHMX correspond to the impact sensitivities of the original cryst. nitramines. This is not entirely valid for e-HNIW. In other words, PBXs with RS-e-HNIW cannot achieve as low a shock sensitivity as would be expected from the differences obtained from the impact sensitivities between RDX, b-HMX and BCHMX, on the one hand, and RS-e-HNIW on the other. It is shown that the morphological stability of RS-e-HNIW in the C4 matrix is insufficient.
dcterms:title
Concerning the Shock Sensitivity of Cyclic Nitramines Incorporated into a Polyisobutylene Matrix Concerning the Shock Sensitivity of Cyclic Nitramines Incorporated into a Polyisobutylene Matrix
skos:prefLabel
Concerning the Shock Sensitivity of Cyclic Nitramines Incorporated into a Polyisobutylene Matrix Concerning the Shock Sensitivity of Cyclic Nitramines Incorporated into a Polyisobutylene Matrix
skos:notation
RIV/00216275:25310/14:39898595!RIV15-MSM-25310___
n3:aktivita
n15:I n15:S
n3:aktivity
I, S
n3:cisloPeriodika
2
n3:dodaniDat
n9:2015
n3:domaciTvurceVysledku
n5:9252355 Elbeih, Ahmed Ikhlas Mohamed n5:8673039 n5:3859908 Yan, Qi Long
n3:druhVysledku
n14:J
n3:duvernostUdaju
n6:S
n3:entitaPredkladatele
n17:predkladatel
n3:idSjednocenehoVysledku
8557
n3:idVysledku
RIV/00216275:25310/14:39898595
n3:jazykVysledku
n12:eng
n3:klicovaSlova
impact; gap test; CL-20; 12-hexaazaisowurtzitane; 10; 8; 6; 4; 12-hexanitro-2; 10; 8; 6; 4; epsilon-2; RDX; beta-HMX; BCHMX
n3:klicoveSlovo
n7:6 n7:8 n7:10 n7:epsilon-2 n7:impact n7:CL-20 n7:4 n7:BCHMX n7:gap%20test n7:beta-HMX n7:12-hexaazaisowurtzitane n7:12-hexanitro-2 n7:RDX
n3:kodStatuVydavatele
PL - Polská republika
n3:kontrolniKodProRIV
[C21D07FCE7CB]
n3:nazevZdroje
Central European Journal of Energetic Materials
n3:obor
n16:CF
n3:pocetDomacichTvurcuVysledku
5
n3:pocetTvurcuVysledku
6
n3:rokUplatneniVysledku
n9:2014
n3:svazekPeriodika
11
n3:tvurceVysledku
Pelikán, Vojtěch Zeman, Svatopluk Yan, Qi Long Elbeih, Ahmed Ikhlas Mohamed Erben, Milan Akstein, Zbynek
n3:wos
000340082600004
s:issn
1733-7178
s:numberOfPages
17
n11:organizacniJednotka
25310