This HTML5 document contains 49 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n12http://localhost/temp/predkladatel/
n16http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n15http://linked.opendata.cz/resource/domain/vavai/projekt/
n14http://linked.opendata.cz/ontology/domain/vavai/
n18http://linked.opendata.cz/resource/domain/vavai/zamer/
n8http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216224%3A14310%2F06%3A00016392%21RIV10-MSM-14310___/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n5http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n19http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n10http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n7http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n11http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n4http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216224%3A14310%2F06%3A00016392%21RIV10-MSM-14310___
rdf:type
skos:Concept n14:Vysledek
dcterms:description
Miniaturization and integration of chemical devices into modules that are dimensionally comparable with electronic chips (Lab on Chip) is nowadays developing worldwide. The aim of our work was to suggest and optimize the best conditions for fabrication of TFT sensor due to its sensitivity and low experimental deviations. New electrochemical analytical device was developed to ensure certain known mass transport to electrodes, which is the most limiting process that influencing the response quality of the sensor. The device consists from rotating conic vessel for measured sample and stick-in thick-film sensor. The sensors responses were tested under trace analysis of cadmium. Measurements were done also with the others electrochemical arrangements to compare with the new one. The sensor output current response dependence on the liquid velocity and geometrical arrangement within using standard electrochemical couple of potassium ferrocyanide-ferricyanide is presented. Miniaturization and integration of chemical devices into modules that are dimensionally comparable with electronic chips (Lab on Chip) is nowadays developing worldwide. The aim of our work was to suggest and optimize the best conditions for fabrication of TFT sensor due to its sensitivity and low experimental deviations. New electrochemical analytical device was developed to ensure certain known mass transport to electrodes, which is the most limiting process that influencing the response quality of the sensor. The device consists from rotating conic vessel for measured sample and stick-in thick-film sensor. The sensors responses were tested under trace analysis of cadmium. Measurements were done also with the others electrochemical arrangements to compare with the new one. The sensor output current response dependence on the liquid velocity and geometrical arrangement within using standard electrochemical couple of potassium ferrocyanide-ferricyanide is presented.
dcterms:title
New hydrodynamic electrochemical arrangement for cadmium ions detection using thick-film chemical sensor electrodes New hydrodynamic electrochemical arrangement for cadmium ions detection using thick-film chemical sensor electrodes
skos:prefLabel
New hydrodynamic electrochemical arrangement for cadmium ions detection using thick-film chemical sensor electrodes New hydrodynamic electrochemical arrangement for cadmium ions detection using thick-film chemical sensor electrodes
skos:notation
RIV/00216224:14310/06:00016392!RIV10-MSM-14310___
n3:aktivita
n7:P n7:Z
n3:aktivity
P(1QS201710508), P(GP525/04/P132), Z(MSM0021622412), Z(MSM0021630503)
n3:cisloPeriodika
6
n3:dodaniDat
n4:2010
n3:domaciTvurceVysledku
n16:2307049 n16:3790185 n16:4995775
n3:druhVysledku
n11:J
n3:duvernostUdaju
n19:S
n3:entitaPredkladatele
n8:predkladatel
n3:idSjednocenehoVysledku
488516
n3:idVysledku
RIV/00216224:14310/06:00016392
n3:jazykVysledku
n10:eng
n3:klicovaSlova
hydrodynamic; electrochemical arrangement; cadmium ions; thick-film chemical sensor electrodes
n3:klicoveSlovo
n5:electrochemical%20arrangement n5:hydrodynamic n5:thick-film%20chemical%20sensor%20electrodes n5:cadmium%20ions
n3:kodStatuVydavatele
CZ - Česká republika
n3:kontrolniKodProRIV
[FC4DEE2A84FE]
n3:nazevZdroje
SENSORS
n3:obor
n17:CG
n3:pocetDomacichTvurcuVysledku
3
n3:pocetTvurcuVysledku
6
n3:projekt
n15:1QS201710508 n15:GP525%2F04%2FP132
n3:rokUplatneniVysledku
n4:2006
n3:svazekPeriodika
11
n3:tvurceVysledku
Adamek, M. Trnková, Libuše Adam, Vojtěch Prasek, J. Hubalek, J. Kizek, René
n3:zamer
n18:MSM0021630503 n18:MSM0021622412
s:issn
1424-8220
s:numberOfPages
5
n12:organizacniJednotka
14310