This HTML5 document contains 44 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n18http://localhost/temp/predkladatel/
n11http://linked.opendata.cz/resource/domain/vavai/projekt/
n6http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n9http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216224%3A14310%2F02%3A00007720%21RIV08-GA0-14310___/
n14http://linked.opendata.cz/ontology/domain/vavai/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n8http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n15http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n16http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n10http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n7http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216224%3A14310%2F02%3A00007720%21RIV08-GA0-14310___
rdf:type
n14:Vysledek skos:Concept
dcterms:description
The electrochemical immunosensor combining three monoclonal antibodies on the same measuring element produced by screen-printing was constructed for the semiquantitative group-specific detection of herbicides belonging to phenoxyalkanoic acids. The combination of different monoclonal antibodies covalently immobilized on three working electrodes and one additional electrode containing immobilized albumin provided a more reliable detection of phenoxyalkanoic acids. Peroxidase-2,4-dichlorophenoxyacetic acid conjugate was used as a tracer suitable for all the antibodies employed in a competitive immunoassay. Several herbicides were used to characterize the immunosensor. The developed immunosensor was tested on samples of surface water spiked with different herbicides and binary mixtures of herbicides. The proposed approach seems feasible for rapid screening of large series of samples for the presence of herbicides. The electrochemical immunosensor combining three monoclonal antibodies on the same measuring element produced by screen-printing was constructed for the semiquantitative group-specific detection of herbicides belonging to phenoxyalkanoic acids. The combination of different monoclonal antibodies covalently immobilized on three working electrodes and one additional electrode containing immobilized albumin provided a more reliable detection of phenoxyalkanoic acids. Peroxidase-2,4-dichlorophenoxyacetic acid conjugate was used as a tracer suitable for all the antibodies employed in a competitive immunoassay. Several herbicides were used to characterize the immunosensor. The developed immunosensor was tested on samples of surface water spiked with different herbicides and binary mixtures of herbicides. The proposed approach seems feasible for rapid screening of large series of samples for the presence of herbicides. The electrochemical immunosensor combining three monoclonal antibodies on the same measuring element produced by screen-printing was constructed for the semiquantitative group-specific detection of herbicides belonging to phenoxyalkanoic acids. The combination of different monoclonal antibodies covalently immobilized on three working electrodes and one additional electrode containing immobilized albumin provided a more reliable detection of phenoxyalkanoic acids. Peroxidase-2,4-dichlorophenoxyacetic acid conjugate was used as a tracer suitable for all the antibodies employed in a competitive immunoassay. Several herbicides were used to characterize the immunosensor. The developed immunosensor was tested on samples of surface water spiked with different herbicides and binary mixtures of herbicides. The proposed approach seems feasible for rapid screening of large series of samples for the presence of herbicides.
dcterms:title
The four-channel electrochemical immunosensor for detection of herbicides based on phenoxyalkanoic acids. The four-channel electrochemical immunosensor for detection of herbicides based on phenoxyalkanoic acids. The four-channel electrochemical immunosensor for detection of herbicides based on phenoxyalkanoic acids.
skos:prefLabel
The four-channel electrochemical immunosensor for detection of herbicides based on phenoxyalkanoic acids. The four-channel electrochemical immunosensor for detection of herbicides based on phenoxyalkanoic acids. The four-channel electrochemical immunosensor for detection of herbicides based on phenoxyalkanoic acids.
skos:notation
RIV/00216224:14310/02:00007720!RIV08-GA0-14310___
n3:strany
101-109
n3:aktivita
n15:P
n3:aktivity
P(GA525/97/0924)
n3:cisloPeriodika
2
n3:dodaniDat
n7:2008
n3:domaciTvurceVysledku
n6:6140769 n6:6669719
n3:druhVysledku
n10:J
n3:duvernostUdaju
n17:S
n3:entitaPredkladatele
n9:predkladatel
n3:idSjednocenehoVysledku
646492
n3:idVysledku
RIV/00216224:14310/02:00007720
n3:jazykVysledku
n12:eng
n3:klicovaSlova
Electrochemical immunosensor; Multichannel biosensor; Herbicides; Phenoxyalkanoic acids
n3:klicoveSlovo
n8:Phenoxyalkanoic%20acids n8:Electrochemical%20immunosensor n8:Herbicides n8:Multichannel%20biosensor
n3:kodStatuVydavatele
GB - Spojené království Velké Británie a Severního Irska
n3:kontrolniKodProRIV
[FF7B3D607545]
n3:nazevZdroje
International Journal of Environmental and Analytical Chemistry
n3:obor
n16:CE
n3:pocetDomacichTvurcuVysledku
2
n3:pocetTvurcuVysledku
2
n3:projekt
n11:GA525%2F97%2F0924
n3:rokUplatneniVysledku
n7:2002
n3:svazekPeriodika
83
n3:tvurceVysledku
Skládal, Petr Kašná, Andrea
s:issn
0306-7319
s:numberOfPages
9
n18:organizacniJednotka
14310