This HTML5 document contains 41 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n6http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216224%3A14110%2F14%3A00074777%21RIV15-MSM-14110___/
dctermshttp://purl.org/dc/terms/
n15http://localhost/temp/predkladatel/
n7http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n3http://linked.opendata.cz/ontology/domain/vavai/
shttp://schema.org/
n5http://linked.opendata.cz/ontology/domain/vavai/riv/
skoshttp://www.w3.org/2004/02/skos/core#
n8http://bibframe.org/vocab/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n14http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n16http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n11http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n13http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n12http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216224%3A14110%2F14%3A00074777%21RIV15-MSM-14110___
rdf:type
n3:Vysledek skos:Concept
dcterms:description
Background The present study was aimed at determining the effect of the tube type used for primary sample collection and the manner of transport prior to assessment (either manual or by pneumatic tube) on the degree of pseudohyperkalaemia in leukaemic patients. Methods Blood from six leukaemic patients was collected into seven primary sample tubes (Monovette, Sarstedt): sample A, heparinized blood gas syringe (potassium reference value); sample B, plasma Li-heparin without separator gel; sample C, plasma Li-heparin with separator gel; and sample D, serum with separator gel. The primary sample tubes designated B, C and D were transported to the laboratory manually. Duplicates of the same sample tubes, BPT, CPT and DPT, were sent to the laboratory by pneumatic tube. Results In patients with chronic lymphocytic leukaemia (CLL), there was no increase in the concentration of potassium in samples B, C and D when compared to the reference value. Background The present study was aimed at determining the effect of the tube type used for primary sample collection and the manner of transport prior to assessment (either manual or by pneumatic tube) on the degree of pseudohyperkalaemia in leukaemic patients. Methods Blood from six leukaemic patients was collected into seven primary sample tubes (Monovette, Sarstedt): sample A, heparinized blood gas syringe (potassium reference value); sample B, plasma Li-heparin without separator gel; sample C, plasma Li-heparin with separator gel; and sample D, serum with separator gel. The primary sample tubes designated B, C and D were transported to the laboratory manually. Duplicates of the same sample tubes, BPT, CPT and DPT, were sent to the laboratory by pneumatic tube. Results In patients with chronic lymphocytic leukaemia (CLL), there was no increase in the concentration of potassium in samples B, C and D when compared to the reference value.
dcterms:title
Pseudohyperkalaemia in leukaemic patients: the effect of test tube type and form of transport to the laboratory Pseudohyperkalaemia in leukaemic patients: the effect of test tube type and form of transport to the laboratory
skos:prefLabel
Pseudohyperkalaemia in leukaemic patients: the effect of test tube type and form of transport to the laboratory Pseudohyperkalaemia in leukaemic patients: the effect of test tube type and form of transport to the laboratory
skos:notation
RIV/00216224:14110/14:00074777!RIV15-MSM-14110___
n5:aktivita
n16:I
n5:aktivity
I
n5:cisloPeriodika
1
n5:dodaniDat
n12:2015
n5:domaciTvurceVysledku
n7:9765069 n7:2574667
n5:druhVysledku
n13:J
n5:duvernostUdaju
n18:S
n5:entitaPredkladatele
n6:predkladatel
n5:idSjednocenehoVysledku
40775
n5:idVysledku
RIV/00216224:14110/14:00074777
n5:jazykVysledku
n11:eng
n5:klicovaSlova
Leukaemia; clinical studies; electrolytes; analytes
n5:klicoveSlovo
n14:electrolytes n14:analytes n14:Leukaemia n14:clinical%20studies
n5:kodStatuVydavatele
US - Spojené státy americké
n5:kontrolniKodProRIV
[A2501885E6A0]
n5:nazevZdroje
Annals of Clinical Biochemistry
n5:obor
n17:CE
n5:pocetDomacichTvurcuVysledku
2
n5:pocetTvurcuVysledku
2
n5:rokUplatneniVysledku
n12:2014
n5:svazekPeriodika
51
n5:tvurceVysledku
Dastych, Milan Čermáková, Zdeňka
n5:wos
000339625900014
s:issn
0004-5632
s:numberOfPages
4
n8:doi
10.1177/0004563213497928
n15:organizacniJednotka
14110