This HTML5 document contains 50 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n17http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216208%3A11310%2F14%3A10283746%21RIV15-MSM-11310___/
n13http://localhost/temp/predkladatel/
n7http://linked.opendata.cz/resource/domain/vavai/projekt/
n4http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n14http://linked.opendata.cz/ontology/domain/vavai/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
rdfshttp://www.w3.org/2000/01/rdf-schema#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n16http://bibframe.org/vocab/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n5http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n11http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n19http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n15http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n20http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n6http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216208%3A11310%2F14%3A10283746%21RIV15-MSM-11310___
rdf:type
n14:Vysledek skos:Concept
rdfs:seeAlso
http://dx.doi.org/10.1002/elan.201400221
dcterms:description
An array of carbon composite electrodes embedded in a 96 well microtitration plate was fabricated and applied for DPV determination of the environmental pollutant triclosan (5-chloro-2-(2,4-dichlorophenoxy)-phenol). For the preparation of composite electrodes, graphite and glassy carbon conductive microparticles were tested in combination with several types of polymers as nonconductive binders. For the measurements, combinations of graphitic carbon particles with polystyrene (C-PS) and with polycarbonate (C-PC) were selected. The achieved limit of detection was 0.49 mu mol L-1 for C-PS electrodes and 0.25 mu mol L-1 for C-PC electrodes in the selected optimum medium. The method was successfully applied for practical samples of river water and toothpaste. An array of carbon composite electrodes embedded in a 96 well microtitration plate was fabricated and applied for DPV determination of the environmental pollutant triclosan (5-chloro-2-(2,4-dichlorophenoxy)-phenol). For the preparation of composite electrodes, graphite and glassy carbon conductive microparticles were tested in combination with several types of polymers as nonconductive binders. For the measurements, combinations of graphitic carbon particles with polystyrene (C-PS) and with polycarbonate (C-PC) were selected. The achieved limit of detection was 0.49 mu mol L-1 for C-PS electrodes and 0.25 mu mol L-1 for C-PC electrodes in the selected optimum medium. The method was successfully applied for practical samples of river water and toothpaste.
dcterms:title
Construction of an Electrochemical Cell System Based on Carbon Composite Film Electrodes and its Application for Voltammetric Determination of Triclosan Construction of an Electrochemical Cell System Based on Carbon Composite Film Electrodes and its Application for Voltammetric Determination of Triclosan
skos:prefLabel
Construction of an Electrochemical Cell System Based on Carbon Composite Film Electrodes and its Application for Voltammetric Determination of Triclosan Construction of an Electrochemical Cell System Based on Carbon Composite Film Electrodes and its Application for Voltammetric Determination of Triclosan
skos:notation
RIV/00216208:11310/14:10283746!RIV15-MSM-11310___
n3:aktivita
n15:I n15:S n15:P
n3:aktivity
I, P(GBP206/12/G151), S
n3:cisloPeriodika
9
n3:dodaniDat
n6:2015
n3:domaciTvurceVysledku
n4:1939181 n4:5768268 n4:6618987 n4:4454472
n3:druhVysledku
n12:J
n3:duvernostUdaju
n11:S
n3:entitaPredkladatele
n17:predkladatel
n3:idSjednocenehoVysledku
8712
n3:idVysledku
RIV/00216208:11310/14:10283746
n3:jazykVysledku
n19:eng
n3:klicovaSlova
Triclosan; Differential pulse voltammetry; Microtitration plate; Composite carbon film electrodes; Array of electrodes
n3:klicoveSlovo
n5:Differential%20pulse%20voltammetry n5:Array%20of%20electrodes n5:Microtitration%20plate n5:Triclosan n5:Composite%20carbon%20film%20electrodes
n3:kodStatuVydavatele
DE - Spolková republika Německo
n3:kontrolniKodProRIV
[F5A6818916A4]
n3:nazevZdroje
Electroanalysis
n3:obor
n20:CG
n3:pocetDomacichTvurcuVysledku
4
n3:pocetTvurcuVysledku
4
n3:projekt
n7:GBP206%2F12%2FG151
n3:rokUplatneniVysledku
n6:2014
n3:svazekPeriodika
26
n3:tvurceVysledku
Barek, Jiří Dejmková, Hana Libánský, Milan Zima, Jiří
n3:wos
000343926700008
s:issn
1040-0397
s:numberOfPages
8
n16:doi
10.1002/elan.201400221
n13:organizacniJednotka
11310