This HTML5 document contains 64 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n20http://localhost/temp/predkladatel/
n17http://linked.opendata.cz/resource/domain/vavai/projekt/
n4http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n7http://linked.opendata.cz/resource/domain/vavai/subjekt/
n6http://linked.opendata.cz/ontology/domain/vavai/
n15http://linked.opendata.cz/resource/domain/vavai/zamer/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
rdfshttp://www.w3.org/2000/01/rdf-schema#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n18http://bibframe.org/vocab/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
n14http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216208%3A11310%2F12%3A10120333%21RIV13-GA0-11310___/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n9http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n19http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n11http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n5http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n22http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n16http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n13http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216208%3A11310%2F12%3A10120333%21RIV13-GA0-11310___
rdf:type
skos:Concept n6:Vysledek
rdfs:seeAlso
http://dx.doi.org/10.1016/j.actbio.2012.01.010
dcterms:description
New colorimetric methods are described for determination of sub-milligram amounts of ultra-high molecular weight polyethylene (UHMWPE) wear particles. These methods are based on the irreversible binding of the fluorescein-conjugated bovine serum albumin or the hydrophobic dye Oil Red O to wear particles. UHMWPE particles bind both substances from their solutions and thus decrease the absorbance of these solutions. The decrease is linearly dependent on the amount of added wear particles in the sub-milligram range suitable for practical use. The newly developed method offers improved accuracy and precision compared to Fourier transformed infrared spectroscopy (Slouf M. et al. Quantification of UHMWPE wear in periprosthetic tissues of hip arthoplasty: description of a new method based on IR and comparison with radiographic appearance. New colorimetric methods are described for determination of sub-milligram amounts of ultra-high molecular weight polyethylene (UHMWPE) wear particles. These methods are based on the irreversible binding of the fluorescein-conjugated bovine serum albumin or the hydrophobic dye Oil Red O to wear particles. UHMWPE particles bind both substances from their solutions and thus decrease the absorbance of these solutions. The decrease is linearly dependent on the amount of added wear particles in the sub-milligram range suitable for practical use. The newly developed method offers improved accuracy and precision compared to Fourier transformed infrared spectroscopy (Slouf M. et al. Quantification of UHMWPE wear in periprosthetic tissues of hip arthoplasty: description of a new method based on IR and comparison with radiographic appearance.
dcterms:title
Simple colorimetric methods for determination of sub-milligram amounts of ultrahigh molecular weight polyethylene wear particles Simple colorimetric methods for determination of sub-milligram amounts of ultrahigh molecular weight polyethylene wear particles
skos:prefLabel
Simple colorimetric methods for determination of sub-milligram amounts of ultrahigh molecular weight polyethylene wear particles Simple colorimetric methods for determination of sub-milligram amounts of ultrahigh molecular weight polyethylene wear particles
skos:notation
RIV/00216208:11310/12:10120333!RIV13-GA0-11310___
n6:predkladatel
n7:orjk%3A11310
n3:aktivita
n5:Z n5:P n5:I
n3:aktivity
I, P(2B06096), P(GAP503/11/0163), P(NT12229), Z(AV0Z40500505), Z(AV0Z40550506)
n3:cisloPeriodika
5
n3:dodaniDat
n13:2013
n3:domaciTvurceVysledku
n4:5789184 n4:1936409 n4:1005057
n3:druhVysledku
n16:J
n3:duvernostUdaju
n19:S
n3:entitaPredkladatele
n14:predkladatel
n3:idSjednocenehoVysledku
167892
n3:idVysledku
RIV/00216208:11310/12:10120333
n3:jazykVysledku
n11:eng
n3:klicovaSlova
number; failure; quantification; oxidation; debris; joint replacements; periprosthetic tissues; hip-arthroplasty; UHMWPE wear; colorimetric methods; wear particles determination; polyethylene wear particles; joint replacement
n3:klicoveSlovo
n9:UHMWPE%20wear n9:oxidation n9:quantification n9:colorimetric%20methods n9:wear%20particles%20determination n9:periprosthetic%20tissues n9:debris n9:hip-arthroplasty n9:joint%20replacement n9:failure n9:polyethylene%20wear%20particles n9:joint%20replacements n9:number
n3:kodStatuVydavatele
NL - Nizozemsko
n3:kontrolniKodProRIV
[38BC569F90A5]
n3:nazevZdroje
Acta Biomaterialia
n3:obor
n22:CC
n3:pocetDomacichTvurcuVysledku
3
n3:pocetTvurcuVysledku
6
n3:projekt
n17:NT12229 n17:2B06096 n17:GAP503%2F11%2F0163
n3:rokUplatneniVysledku
n13:2012
n3:svazekPeriodika
8
n3:tvurceVysledku
Špundová, Marcela Entlicher, Gustav Šlouf, Miroslav Zolotarevová, Eva Kaftan, Filip Veselý, Filip
n3:wos
000302989700028
n3:zamer
n15:AV0Z40500505 n15:AV0Z40550506
s:issn
1742-7061
s:numberOfPages
4
n18:doi
10.1016/j.actbio.2012.01.010
n20:organizacniJednotka
11310