This HTML5 document contains 46 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
n16http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216208%3A11150%2F14%3A10284259%21RIV15-MSM-11150___/
dctermshttp://purl.org/dc/terms/
n11http://localhost/temp/predkladatel/
n5http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n12http://linked.opendata.cz/ontology/domain/vavai/
shttp://schema.org/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/
rdfshttp://www.w3.org/2000/01/rdf-schema#
skoshttp://www.w3.org/2004/02/skos/core#
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n8http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n9http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n18http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n15http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n17http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n7http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n13http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216208%3A11150%2F14%3A10284259%21RIV15-MSM-11150___
rdf:type
n12:Vysledek skos:Concept
rdfs:seeAlso
http://www.cskb.cz/res/file/KBM-pdf/2014/2014-4/KBM-4-2014-Pudil-203.pdf
dcterms:description
Tato práce sleduje pacienty s akutním koronárním syndromem a k diagnostice akutního infarktu myokardu (AIM) využívá zcela nové technologie proteinových biočipů. Snahou je nejenom ohodnotit tuto novou možnost laboratorní diagnostiky AIM, ale také srovnání méně známých kardiomarkerů se standardními markery a posouzení jejich vztahu ke klinickým parametrům. Materiál a metody: Do studie bylo celkem zařazeno 44 pacientů s diagnózou AIM a krevní odběry byly prováděny v den přijetí, za 24 hodin a poté čtvrtý nebo pátý den hospitalizace. Z kardiomarkerů byl testován panel Cardiac Array (cTnI, CK MB, myoglobin, CAIII, FABP a GPBB) na biočipovém analyzátoru The Evidence Investigator TM od firmy Randox (Randox Laboratories Ltd., Velká Británie). Výsledky: Naše práce potvrdila těsný vztah FABP a GPBB k AIM a na základě jejich dynamiky je můžeme považovat za časné kardiomarkery. Zároveň jsme zjistili, že FABP má, stejně jako standardní marker CKMB nebo TnI, také prognostický význam - vyšší hodnoty jsou spojené se systolickou dysfunkcí. Také jsme poukázali na možnost využití biočipového analyzátoru při diagnostice AIM, kdy za poměrně krátký časový úsek získáme výsledky několika analytů najednou, které nám tak podají širší informace o probíhajícím AIM. Metoda proteinových biočipů představuje v diagnostice AIM nový efektivní přístup, který ale jistě ke svému rozšíření vyžaduje řadu dalších studií. Závěr: Metoda proteinových biočipů představuje v diagnostice AIM nový efektivní přístup, který ale jistě ke svému rozšíření vyžaduje řadu dalších studií. Objective: This study observes patients with acute coronary syndromes. To the diagnosis of acute myocardial infarction (AIM) we use the new proteins biochip technologies. The aim of this study is to evaluate the new strategy of laboratory diagnostic method and to confront the less known's cardio markers with the standard markers and with the clinical parameters. Material and methods: This study contains 44 patients with AIM and the blood samples were taken in the time of the admission, 24 hours later and then the fourth or fifth day of hospitalization. We tested the cardiac panel Cardiac Array (cTnI, CK MB, myoglobin, CAIII, FABP and GPBB) on the biochip analyser The Evidence Investigator TM from Randox (Randox Laboratories Ltd., United Kingdom). Results: Our study confirms the close relationship between FABP and GPBB to AIM and we can consider these markers as early markers in the diagnosis of AIM. FABP has, as the standard markers CKMB or TnI, the prognostic value too (the higher values are associated with he systolic dysfunction). This study employs a new strategy of the biochip analyser in the diagnosis of AIM (in the same time we have the concentrations of more parameters and complex information about AIM). Conclusion: This method presents new interesting multianalytes approach to the diagnosis of the AIM. But this method requires a lot of further studies to verify this technology. Tato práce sleduje pacienty s akutním koronárním syndromem a k diagnostice akutního infarktu myokardu (AIM) využívá zcela nové technologie proteinových biočipů. Snahou je nejenom ohodnotit tuto novou možnost laboratorní diagnostiky AIM, ale také srovnání méně známých kardiomarkerů se standardními markery a posouzení jejich vztahu ke klinickým parametrům. Materiál a metody: Do studie bylo celkem zařazeno 44 pacientů s diagnózou AIM a krevní odběry byly prováděny v den přijetí, za 24 hodin a poté čtvrtý nebo pátý den hospitalizace. Z kardiomarkerů byl testován panel Cardiac Array (cTnI, CK MB, myoglobin, CAIII, FABP a GPBB) na biočipovém analyzátoru The Evidence Investigator TM od firmy Randox (Randox Laboratories Ltd., Velká Británie). Výsledky: Naše práce potvrdila těsný vztah FABP a GPBB k AIM a na základě jejich dynamiky je můžeme považovat za časné kardiomarkery. Zároveň jsme zjistili, že FABP má, stejně jako standardní marker CKMB nebo TnI, také prognostický význam - vyšší hodnoty jsou spojené se systolickou dysfunkcí. Také jsme poukázali na možnost využití biočipového analyzátoru při diagnostice AIM, kdy za poměrně krátký časový úsek získáme výsledky několika analytů najednou, které nám tak podají širší informace o probíhajícím AIM. Metoda proteinových biočipů představuje v diagnostice AIM nový efektivní přístup, který ale jistě ke svému rozšíření vyžaduje řadu dalších studií. Závěr: Metoda proteinových biočipů představuje v diagnostice AIM nový efektivní přístup, který ale jistě ke svému rozšíření vyžaduje řadu dalších studií.
dcterms:title
Utilization protein biochips in diagnostics ischemic damage infarction Využití proteinových biočipů v diagnostice ischemického poškození myokardu Využití proteinových biočipů v diagnostice ischemického poškození myokardu
skos:prefLabel
Utilization protein biochips in diagnostics ischemic damage infarction Využití proteinových biočipů v diagnostice ischemického poškození myokardu Využití proteinových biočipů v diagnostice ischemického poškození myokardu
skos:notation
RIV/00216208:11150/14:10284259!RIV15-MSM-11150___
n4:aktivita
n18:I
n4:aktivity
I
n4:cisloPeriodika
4
n4:dodaniDat
n13:2015
n4:domaciTvurceVysledku
n5:7447825 n5:2398559 n5:9496548
n4:druhVysledku
n7:J
n4:duvernostUdaju
n9:S
n4:entitaPredkladatele
n16:predkladatel
n4:idSjednocenehoVysledku
55138
n4:idVysledku
RIV/00216208:11150/14:10284259
n4:jazykVysledku
n15:cze
n4:klicovaSlova
systolic dysfunction; cardiac markers; protein biochip; acute myocardial infarction
n4:klicoveSlovo
n8:protein%20biochip n8:acute%20myocardial%20infarction n8:cardiac%20markers n8:systolic%20dysfunction
n4:kodStatuVydavatele
CZ - Česká republika
n4:kontrolniKodProRIV
[B64626BD0AD4]
n4:nazevZdroje
Klinická biochemie a metabolismus
n4:obor
n17:FE
n4:pocetDomacichTvurcuVysledku
3
n4:pocetTvurcuVysledku
4
n4:rokUplatneniVysledku
n13:2014
n4:svazekPeriodika
22
n4:tvurceVysledku
Pudil, Radek Vašatová, Martina Tichý, Miloš Horáková, Lucie
s:issn
1210-7921
s:numberOfPages
5
n11:organizacniJednotka
11150