This HTML5 document contains 44 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n17http://localhost/temp/predkladatel/
n18http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n11http://linked.opendata.cz/resource/domain/vavai/projekt/
n12http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00216208%3A11120%2F09%3A00001668%21RIV10-GA0-11120___/
n10http://linked.opendata.cz/ontology/domain/vavai/
n4http://linked.opendata.cz/resource/domain/vavai/zamer/
shttp://schema.org/
skoshttp://www.w3.org/2004/02/skos/core#
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n5http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n6http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n14http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n8http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n16http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n15http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n9http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00216208%3A11120%2F09%3A00001668%21RIV10-GA0-11120___
rdf:type
skos:Concept n10:Vysledek
dcterms:description
A contactless conductivity detector (C4D) performance has been tested on a simple capillary electrophoretic separation in a standard fused-silica capillary with an external diameter of 360 μm and in a thin-walled capillary (an external diameter of 150 μm); the internal diameters of the two capillaries were identical, equal to 75 μm. Potassium and sodium ions have been separated in a morpholinoethanesulfonic acid/histidine background electrolyte (MES/His), over a wide range of its concentrations (0 - 100 mM). At low MES/His concentrations, the C4D response, obtained from the height of the potassium peak, is by 100 to 200 per cent higher for the thin-walled capillary and the calibration dependences are linear, in contrast to the thick-walled capillary. These differences between the two capillaries decrease with increasing MES/His concentration, the C4D response in the thin-walled capillary is then higher by mere 20 per cent and the calibration dependences are linear in both the capillarie A contactless conductivity detector (C4D) performance has been tested on a simple capillary electrophoretic separation in a standard fused-silica capillary with an external diameter of 360 μm and in a thin-walled capillary (an external diameter of 150 μm); the internal diameters of the two capillaries were identical, equal to 75 μm. Potassium and sodium ions have been separated in a morpholinoethanesulfonic acid/histidine background electrolyte (MES/His), over a wide range of its concentrations (0 - 100 mM). At low MES/His concentrations, the C4D response, obtained from the height of the potassium peak, is by 100 to 200 per cent higher for the thin-walled capillary and the calibration dependences are linear, in contrast to the thick-walled capillary. These differences between the two capillaries decrease with increasing MES/His concentration, the C4D response in the thin-walled capillary is then higher by mere 20 per cent and the calibration dependences are linear in both the capillarie
dcterms:title
The Dependence of the Sensitivity and Reliability of Contactless Conductivity Detection on the Wall Thickness of Electrophoretic Fused-Silica Capillaries The Dependence of the Sensitivity and Reliability of Contactless Conductivity Detection on the Wall Thickness of Electrophoretic Fused-Silica Capillaries
skos:prefLabel
The Dependence of the Sensitivity and Reliability of Contactless Conductivity Detection on the Wall Thickness of Electrophoretic Fused-Silica Capillaries The Dependence of the Sensitivity and Reliability of Contactless Conductivity Detection on the Wall Thickness of Electrophoretic Fused-Silica Capillaries
skos:notation
RIV/00216208:11120/09:00001668!RIV10-GA0-11120___
n3:aktivita
n8:Z n8:P
n3:aktivity
P(GA203/07/0896), P(IAA400400704), Z(MSM0021620814)
n3:cisloPeriodika
3-5
n3:dodaniDat
n9:2010
n3:domaciTvurceVysledku
n18:2944146 n18:5923492
n3:druhVysledku
n15:J
n3:duvernostUdaju
n6:S
n3:entitaPredkladatele
n12:predkladatel
n3:idSjednocenehoVysledku
309483
n3:idVysledku
RIV/00216208:11120/09:00001668
n3:jazykVysledku
n14:eng
n3:klicovaSlova
Capillary electrophoresis; contactless conductivity detection; thickness of capillary wall
n3:klicoveSlovo
n5:contactless%20conductivity%20detection n5:Capillary%20electrophoresis n5:thickness%20of%20capillary%20wall
n3:kodStatuVydavatele
DE - Spolková republika Německo
n3:kontrolniKodProRIV
[4C6263A3481F]
n3:nazevZdroje
Electroanalysis
n3:obor
n16:CG
n3:pocetDomacichTvurcuVysledku
2
n3:pocetTvurcuVysledku
3
n3:projekt
n11:GA203%2F07%2F0896 n11:IAA400400704
n3:rokUplatneniVysledku
n9:2009
n3:svazekPeriodika
21
n3:tvurceVysledku
Tůma, Petr Samcová, Eva Štulík, Karel
n3:wos
000264063500049
n3:zamer
n4:MSM0021620814
s:issn
1040-0397
s:numberOfPages
5
n17:organizacniJednotka
11120