This HTML5 document contains 55 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n7http://linked.opendata.cz/resource/domain/vavai/projekt/
n5http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n17http://linked.opendata.cz/ontology/domain/vavai/
shttp://schema.org/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/
skoshttp://www.w3.org/2004/02/skos/core#
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n13http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00023001%3A_____%2F09%3A00002167%21RIV10-MZ0-00023001/
n8http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n6http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n16http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n11http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n15http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n12http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n10http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00023001%3A_____%2F09%3A00002167%21RIV10-MZ0-00023001
rdf:type
skos:Concept n17:Vysledek
dcterms:description
Objective ? Multidetector-row CT (MDCT) and contrast-enhanced echocardiography (CEE) are being increasingly used for assessment of left ventricular (LV) function. Excellent spatial and contrast resolution of MDCT allows this evaluation along with coronary angiography. CEE improves the accuracy of 2D echocardiography. Data on side-by-side comparison of both techniques for assessment of LV size and function in subjects with a non-dilated or dilated left ventricle are limited. Methods and results ? Our study population included 64 patients. Group I included 31 patients with an implanted pacemaker who had a non-dilated left ventricle with preserved systolic function. Group II comprised 33 patients with dilated cardiomyopathy and severe systolic LV dysfunction. LV end-diastolic and end-systolic volumes (LVEDV, LVESV) and ejection fraction (LVEF) were assessed using both CEE and short-axis MDCT. The results obtained by both techniques were compared by linear regression and Bland-Altman analysis. Additional Objective ? Multidetector-row CT (MDCT) and contrast-enhanced echocardiography (CEE) are being increasingly used for assessment of left ventricular (LV) function. Excellent spatial and contrast resolution of MDCT allows this evaluation along with coronary angiography. CEE improves the accuracy of 2D echocardiography. Data on side-by-side comparison of both techniques for assessment of LV size and function in subjects with a non-dilated or dilated left ventricle are limited. Methods and results ? Our study population included 64 patients. Group I included 31 patients with an implanted pacemaker who had a non-dilated left ventricle with preserved systolic function. Group II comprised 33 patients with dilated cardiomyopathy and severe systolic LV dysfunction. LV end-diastolic and end-systolic volumes (LVEDV, LVESV) and ejection fraction (LVEF) were assessed using both CEE and short-axis MDCT. The results obtained by both techniques were compared by linear regression and Bland-Altman analysis. Additional
dcterms:title
Assessment of left ventricular function in non-dilated and dilated hearts: Comparison of contrast-enhanced 2-dimensional echocardiography with multi-detector row CT angiography Assessment of left ventricular function in non-dilated and dilated hearts: Comparison of contrast-enhanced 2-dimensional echocardiography with multi-detector row CT angiography
skos:prefLabel
Assessment of left ventricular function in non-dilated and dilated hearts: Comparison of contrast-enhanced 2-dimensional echocardiography with multi-detector row CT angiography Assessment of left ventricular function in non-dilated and dilated hearts: Comparison of contrast-enhanced 2-dimensional echocardiography with multi-detector row CT angiography
skos:notation
RIV/00023001:_____/09:00002167!RIV10-MZ0-00023001
n4:aktivita
n11:P
n4:aktivity
P(NR8541), P(NR8553)
n4:cisloPeriodika
6
n4:dodaniDat
n10:2010
n4:domaciTvurceVysledku
n5:6599370 n5:6123228 n5:7990812 n5:3891070 n5:5202965 n5:6017207 n5:6103227 n5:6873472 n5:6807437
n4:druhVysledku
n12:J
n4:duvernostUdaju
n6:S
n4:entitaPredkladatele
n13:predkladatel
n4:idSjednocenehoVysledku
304199
n4:idVysledku
RIV/00023001:_____/09:00002167
n4:jazykVysledku
n16:eng
n4:klicovaSlova
Echocardiography; CT angiography; left ventricular volume; left ventricular function
n4:klicoveSlovo
n8:left%20ventricular%20volume n8:CT%20angiography n8:Echocardiography n8:left%20ventricular%20function
n4:kodStatuVydavatele
BE - Belgické království
n4:kontrolniKodProRIV
[3EFE3F8FE08E]
n4:nazevZdroje
Acta cardiologica
n4:obor
n15:FA
n4:pocetDomacichTvurcuVysledku
9
n4:pocetTvurcuVysledku
9
n4:projekt
n7:NR8541 n7:NR8553
n4:rokUplatneniVysledku
n10:2009
n4:svazekPeriodika
64
n4:tvurceVysledku
Vedlich, Daniel Lefflerová, Kateřina Kautzner, Josef Marek, Tomáš Kautznerová, Dana Burianová, Lucie Lánská, Věra Lupínek, Petr Riedlbauchová, Lucie
n4:wos
000273486700012
s:issn
0001-5385
s:numberOfPages
8