This HTML5 document contains 48 embedded RDF statements represented using HTML+Microdata notation.

The embedded RDF content will be recognized by any processor of HTML5 Microdata.

Namespace Prefixes

PrefixIRI
dctermshttp://purl.org/dc/terms/
n13http://localhost/temp/predkladatel/
n8http://linked.opendata.cz/resource/domain/vavai/projekt/
n5http://linked.opendata.cz/resource/domain/vavai/riv/tvurce/
n17http://linked.opendata.cz/ontology/domain/vavai/
skoshttp://www.w3.org/2004/02/skos/core#
n12http://linked.opendata.cz/resource/domain/vavai/vysledek/RIV%2F00000493%3AG39__%2F05%3A%230000002%21RIV06-MO0-G39_____/
n3http://linked.opendata.cz/ontology/domain/vavai/riv/
n18http://linked.opendata.cz/ontology/domain/vavai/riv/licencniPoplatek/
n2http://linked.opendata.cz/resource/domain/vavai/vysledek/
rdfhttp://www.w3.org/1999/02/22-rdf-syntax-ns#
n14http://linked.opendata.cz/ontology/domain/vavai/riv/vyuzitiJinymSubjektem/
n4http://linked.opendata.cz/ontology/domain/vavai/riv/klicoveSlovo/
n19http://linked.opendata.cz/ontology/domain/vavai/riv/duvernostUdaju/
xsdhhttp://www.w3.org/2001/XMLSchema#
n15http://linked.opendata.cz/ontology/domain/vavai/riv/aktivita/
n11http://linked.opendata.cz/ontology/domain/vavai/riv/jazykVysledku/
n16http://linked.opendata.cz/ontology/domain/vavai/riv/obor/
n9http://linked.opendata.cz/ontology/domain/vavai/riv/druhVysledku/
n6http://reference.data.gov.uk/id/gregorian-year/

Statements

Subject Item
n2:RIV%2F00000493%3AG39__%2F05%3A%230000002%21RIV06-MO0-G39_____
rdf:type
n17:Vysledek skos:Concept
dcterms:description
V souladu s cílem řešení projektu „Monitorování narušení integrity stínění a stavu stínicí účinnosti stínicích krytů - STÍNĚNÍ“ bylo po provedení ověření možností dvou monitorovacích souprav (soupravy vysílače QCC s přijímačem IC-R3 a soupravy MF-130D) zpracovány metodiky využití těchto souprav. Metodiky předně obsahují popis ovládání souprav a jejich určení, kontrolu pracovní způsobilosti a kalibraci před použitím, postupy monitorování stínicí účinnosti, využití souprav pro vyhledávání průsaků elektromagnetické energie stínicí bariérou krytu a způsoby vyhodnocení monitoringu. V souladu s cílem řešení projektu „Monitorování narušení integrity stínění a stavu stínicí účinnosti stínicích krytů - STÍNĚNÍ“ bylo po provedení ověření možností dvou monitorovacích souprav (soupravy vysílače QCC s přijímačem IC-R3 a soupravy MF-130D) zpracovány metodiky využití těchto souprav. Metodiky předně obsahují popis ovládání souprav a jejich určení, kontrolu pracovní způsobilosti a kalibraci před použitím, postupy monitorování stínicí účinnosti, využití souprav pro vyhledávání průsaků elektromagnetické energie stínicí bariérou krytu a způsoby vyhodnocení monitoringu. According to aim of project „ Monitoring of shielding integrity degradation and state of shielding effectivnes of shielding rooms – Shielding”, procedures of using monitoring sets (transmeter QCC with receiver IC-R3 and MF-130D) were created, after verification its operating facility. Procedures firstly contain description of monitoring sets operation and monitoring sets determination. Next it contains verification of their work eligibility and calibration before use, technology shielding effectiveness monitoring, using sets for searching electromagnetic leakage points and ways of monitoring interpretation.
dcterms:title
Procedure of QCC/IC-R3 and MF-130D monitoring set utilization Metodika využití monitorovací soupravy QCC/IC-R3 a MF-130D Metodika využití monitorovací soupravy QCC/IC-R3 a MF-130D
skos:prefLabel
Metodika využití monitorovací soupravy QCC/IC-R3 a MF-130D Metodika využití monitorovací soupravy QCC/IC-R3 a MF-130D Procedure of QCC/IC-R3 and MF-130D monitoring set utilization
skos:notation
RIV/00000493:G39__/05:#0000002!RIV06-MO0-G39_____
n3:aktivita
n15:P
n3:aktivity
P(ONVTUPV200304)
n3:dodaniDat
n6:2006
n3:domaciTvurceVysledku
n5:7037228 n5:3657027
n3:druhVysledku
n9:T
n3:duvernostUdaju
n19:S
n3:ekonomickeParametry
Využití souprav zajistí znalost stavu stínicí účinnosti krytů při snížení četnosti nákladných měření zajišťovaných akreditovanými laboratořemi, což umožní provozovateli realizovat optimální údržbu a ošetřování krytů při dosažení provozních úspor.
n3:entitaPredkladatele
n12:predkladatel
n3:idSjednocenehoVysledku
529894
n3:idVysledku
RIV/00000493:G39__/05:#0000002
n3:interniIdentifikace
23/2611/001
n3:jazykVysledku
n11:cze
n3:klicovaSlova
Electromagnetic Compatibility; Shielding Room; Shielding Effectivenes (SE); Monitoring SE; Degradation SE, IC-R3; QCC; MF-130D
n3:klicoveSlovo
n4:Electromagnetic%20Compatibility n4:Monitoring%20SE n4:QCC n4:Degradation%20SE n4:Shielding%20Effectivenes%20%28SE%29 n4:Shielding%20Room n4:IC-R3 n4:MF-130D
n3:kontrolniKodProRIV
[F88E35A78B67]
n3:licencniPoplatek
n18:N
n3:lokalizaceVysledku
VOP-026 Šternberk, s.p., divize VTÚPV Vyškov
n3:obor
n16:KA
n3:pocetDomacichTvurcuVysledku
6
n3:pocetTvurcuVysledku
6
n3:projekt
n8:ONVTUPV200304
n3:rokUplatneniVysledku
n6:2005
n3:technickeParametry
Obě metodiky využití monitorovacích souprav QCC/IC-R3 a MF-130D obsahují metodické pokyny pro praktické použití souprav při pravidelné kontrole elektromagnetické stínicí účinnosti provozovaných stínicích krytů
n3:tvurceVysledku
Suchý, Luboš Váňa, Vladimír
n3:vlastnik
n12:vlastnikVysledku
n3:vyuzitiJinymSubjektem
n14:P
n13:organizacniJednotka
G39