About: Angular dependence of two different (LiF based) eye lens TL dosemeters     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • The dose limit for the eye lens has been lowered, which is the reason why new ways to quantify the irradiation of eye lens more precisely are developed. A new model of eye lens dosimeter designed in ORAMED project was considered in this work. The dosimeter was attached on the right eye of the antropomorphic Rando phantom and irradiated under laboratory conditions. Its angular dependence was investigated for X-ray spectra N40 and N60. The obtained results were compared with data of theoretical angular dependence of personal dose equivalent at the depth of 3 mm, Hp(3). The measurements were performed for two types of TL (thermoluminescent) detectors, LiF:Mg,Ti and LiF:Mg,Cu,P. Their angular response seems to be very similar in a large range of angles, and both the materials can be used for Hp(3) measurements in interventional radiology.
  • The dose limit for the eye lens has been lowered, which is the reason why new ways to quantify the irradiation of eye lens more precisely are developed. A new model of eye lens dosimeter designed in ORAMED project was considered in this work. The dosimeter was attached on the right eye of the antropomorphic Rando phantom and irradiated under laboratory conditions. Its angular dependence was investigated for X-ray spectra N40 and N60. The obtained results were compared with data of theoretical angular dependence of personal dose equivalent at the depth of 3 mm, Hp(3). The measurements were performed for two types of TL (thermoluminescent) detectors, LiF:Mg,Ti and LiF:Mg,Cu,P. Their angular response seems to be very similar in a large range of angles, and both the materials can be used for Hp(3) measurements in interventional radiology. (en)
Title
  • Angular dependence of two different (LiF based) eye lens TL dosemeters
  • Angular dependence of two different (LiF based) eye lens TL dosemeters (en)
skos:prefLabel
  • Angular dependence of two different (LiF based) eye lens TL dosemeters
  • Angular dependence of two different (LiF based) eye lens TL dosemeters (en)
skos:notation
  • RIV/86652052:_____/14:#0000248!RIV15-MV0-86652052
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 3289
http://linked.open...ai/riv/idVysledku
  • RIV/86652052:_____/14:#0000248
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • eye lens dosemeter; angular dependence; LiF detector (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [3E003EED3A8F]
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Ekendahl, Daniela
  • Čemusová, Zina
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software