About: Results of prostate IMRT audit - dosimetric verification     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • In 2013 National Radiation Protection Institute performed on-site IMRT audit at all 17 Czech radiotherapy departments, which use IMRT technique for treatment of prostate cancer patients. This audit represents independent end-to-end test using anthropomorphic pelvic PMMA phantom with inhomogeneities (bones). Paper presents dosimetry results of the audits (beam calibration check, agreement of measured and calculated doses in PTV and in rectum, planar dose distributions). Point doses were measured by ionization chambers, dose distributions were measured by EBT2 gafchromic films. Deviation of dose during beam calibration check exceeded tolerance level of 2% in one case. Deviation of dose in PTV exceeded tolerance level of 3% in 4 cases. (en)
  • Státní ústav radiační ochrany provedl v průběhu roku 2013 on-site IMRT audit prostaty na všech 17 radioterapeutických pracovištích v ČR, kde léčí pacienty s karcinomem prostaty technikou IMRT. Tento audit představuje nezávislý end-to-end test využívající antropomorfní fantom pánve (z PMMA) s nehomogenitami (kostmi). V článku jsou prezentovány dozimetrické výsledky auditů (ověření kalibrace svazku, shoda změřených a vypočtených dávek v cílovém objemu a v rektu, shoda planárních dávkových distribucí). Bodové dávky byly změřeny pomocí ionizačních komor, dávkové distribuce se měřily pomocí gafchromických filmů EBT2. Jedno pracoviště při ověření kalibrace svazku nevyhovělo toleranci ± 2%. Čtyři pracoviště při ověření dávky v cílovém objemu nevyhověla toleranci ± 3%.
  • Státní ústav radiační ochrany provedl v průběhu roku 2013 on-site IMRT audit prostaty na všech 17 radioterapeutických pracovištích v ČR, kde léčí pacienty s karcinomem prostaty technikou IMRT. Tento audit představuje nezávislý end-to-end test využívající antropomorfní fantom pánve (z PMMA) s nehomogenitami (kostmi). V článku jsou prezentovány dozimetrické výsledky auditů (ověření kalibrace svazku, shoda změřených a vypočtených dávek v cílovém objemu a v rektu, shoda planárních dávkových distribucí). Bodové dávky byly změřeny pomocí ionizačních komor, dávkové distribuce se měřily pomocí gafchromických filmů EBT2. Jedno pracoviště při ověření kalibrace svazku nevyhovělo toleranci ± 2%. Čtyři pracoviště při ověření dávky v cílovém objemu nevyhověla toleranci ± 3%. (cs)
Title
  • Results of prostate IMRT audit - dosimetric verification
  • Results of prostate IMRT audit - dosimetric verification (cs)
  • Výsledky IMRT auditu prostaty – dozimetrická verifikace (en)
skos:prefLabel
  • Results of prostate IMRT audit - dosimetric verification
  • Results of prostate IMRT audit - dosimetric verification (cs)
  • Výsledky IMRT auditu prostaty – dozimetrická verifikace (en)
skos:notation
  • RIV/86652052:_____/14:#0000209!RIV15-TA0-86652052
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(TB01SUJB071)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 42522
http://linked.open...ai/riv/idVysledku
  • RIV/86652052:_____/14:#0000209
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • IMRT audit; dosimetric verification; end-to-end test (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...i/riv/kodPristupu
http://linked.open...ontrolniKodProRIV
  • [CD442B1F18D7]
http://linked.open...i/riv/mistoVydani
  • Hradec Králové
http://linked.open...telVyzkumneZpravy
  • Klinika onkologie a radioterapie LFUK a FN Hradec Králové
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Dufek, Vladimír
  • Horáková, Ivana
  • Koniarová, Irena
https://schema.org/isbn
  • 978-80-905446-1-1
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 112 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software