  • Recently, the role of energy savings in indoor air quality deterioration has been extensively emphasized, predominantly in the context of significant air exchange rate reduction as a result of home energy retrofits. In case of refurbishment of existing buildings, the effect of energy-efficient technologies on indoor radon concentration is considerably complex and has to be carefully evaluated in respect to radon entry rate and air exchange rate alteration. For the purpose of detailed analysis of radon entry pathways, the unique infiltration experiment has been carried out using the tracer gas (N2O) method application in field conditions. Significant amount of experimental works has been done to provide an independent assessment of radon entry rate and air-exchange rate facilitating the analysis of fundamental factors influencing the indoor radon variations (e.g. indoor-outdoor pressure difference induced by wind; stack effect; heating, ventilation, and air conditioning systems operation).
  • Recently, the role of energy savings in indoor air quality deterioration has been extensively emphasized, predominantly in the context of significant air exchange rate reduction as a result of home energy retrofits. In case of refurbishment of existing buildings, the effect of energy-efficient technologies on indoor radon concentration is considerably complex and has to be carefully evaluated in respect to radon entry rate and air exchange rate alteration. For the purpose of detailed analysis of radon entry pathways, the unique infiltration experiment has been carried out using the tracer gas (N2O) method application in field conditions. Significant amount of experimental works has been done to provide an independent assessment of radon entry rate and air-exchange rate facilitating the analysis of fundamental factors influencing the indoor radon variations (e.g. indoor-outdoor pressure difference induced by wind; stack effect; heating, ventilation, and air conditioning systems operation). (en)
Title
  • Radon entry rate analyses using in-situ tracer gas method aplication (en)
  • Radon entry rate analyses using in-situ tracer gas method aplication
skos:prefLabel
  • Radon entry rate analyses using in-situ tracer gas method aplication (en)
  • Radon entry rate analyses using in-situ tracer gas method aplication
skos:notation
  • RIV/86652052:_____/13:#0000171!RIV14-TA0-86652052
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(TB01SUJB072)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 101369
http://linked.open...ai/riv/idVysledku
  • RIV/86652052:_____/13:#0000171
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • radon entry; air-exchange rate; tracer gas (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [8A710D010AEF]
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Froňka, Aleš
  • Jílek, Karel
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software