Attributes | Values |
---|
rdf:type
| |
Description
| - Portable USB spectrometer (Multichannel analyzer) used mainly for detection of alpha particles was developed. The device has three parts - i] digital (Digital Signal Processor with sampling ADC, RAM/ROM memories, 14 bits/20Msps ADC; 16 bits/160 MIPS DSP; 1 MB RAM), ii) analog module and iii) USB 2.0 controller. Analog module has following features: both bias polarities, both polarities of output signals, different shaping times, selectable energy ranges (amplification), fast and slow triggers, good FWHM (noise measured by Si detector for 0 pF = 4,5 keV, for 100 pF = 9,0 keV), bias for detector up to 500 V. Module was produced by smd technology, It is designed as a flexible multipurpose unit, which can be easily modified to meet specific requests of the experimental conditions (e.g. it works as simple digital osciloscope).
- Portable USB spectrometer (Multichannel analyzer) used mainly for detection of alpha particles was developed. The device has three parts - i] digital (Digital Signal Processor with sampling ADC, RAM/ROM memories, 14 bits/20Msps ADC; 16 bits/160 MIPS DSP; 1 MB RAM), ii) analog module and iii) USB 2.0 controller. Analog module has following features: both bias polarities, both polarities of output signals, different shaping times, selectable energy ranges (amplification), fast and slow triggers, good FWHM (noise measured by Si detector for 0 pF = 4,5 keV, for 100 pF = 9,0 keV), bias for detector up to 500 V. Module was produced by smd technology, It is designed as a flexible multipurpose unit, which can be easily modified to meet specific requests of the experimental conditions (e.g. it works as simple digital osciloscope). (en)
|
Title
| - Portable USB spectrometer for detection of radon
- Portable USB spectrometer for detection of radon (en)
|
skos:prefLabel
| - Portable USB spectrometer for detection of radon
- Portable USB spectrometer for detection of radon (en)
|
skos:notation
| - RIV/68407700:21670/12:00203005!RIV13-TA0-21670___
|
http://linked.open...avai/predkladatel
| |
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...onomickeParametry
| - Finální cena přístroje pro zákazníka je stanovena na 10000 Kč v případě odběru 1 kusu.
|
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/68407700:21670/12:00203005
|
http://linked.open...terniIdentifikace
| - Portable USB spectrometer
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open...vai/riv/kategorie
| |
http://linked.open.../riv/klicovaSlova
| - spectroscopy; digital processing; USB interface; ionizing radiation; radiation detectors; multichannel analyzers (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open.../licencniPoplatek
| |
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...echnickeParametry
| - 14 bitů/20Msps ADC; 16 bitů/160 MIPS DSP; 1 MB RAM; USB 2.0; both bias polarities, different shaping times, fast trigger, FWHM (noise measured by Si detector for 0 pF = 4,5 keV).
|
http://linked.open...iv/tvurceVysledku
| - Štekl, Ivan
- Mamedov, Fadahat
- Petřík, Milan
- Přidal, Petr
- Kouba, Petr
- Vlášek, Jakub
|
http://linked.open...avai/riv/vlastnik
| |
http://linked.open...itiJinymSubjektem
| |
http://localhost/t...ganizacniJednotka
| |