About: Precise energy calibration of pixel detector working in time-over-threshold mode     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • The semiconductor pixel detector Timepix (256 x 256 pixels with pitch of 55 mu m) is a successor of the Medipix2 device. Each Timepix pixel can be independently operated in one of three possible modes: (1) counting of the detected particles; (2) measurement of the particle energy; and (3) measurement of the time of interaction. The energy measurement in the second mode is performed via the determination of the %22time-over-threshold%22 (TOT). The energy measurement with the Timepix detector in TOT mode requires knowledge of the energy calibration of each pixel of the matrix. Such calibration is very nonlinear in the low energy range and can be described by a surrogate function depending on four parameters. The determination of all these parameters can be performed by measurement and evaluation of the response of each pixel in at least four calibration points. The procedure is extremely demanding: it requires the analysis of at least 250 thousand spectra and the performance of 330 thousand least-squares fits. In this article, it is demonstrated that even better result can be achieved with only two or three calibration points halving the number of least-squares fits needed. The method is based on precise analysis of the shape of spectral peaks. The article also discusses the performance of energy calibrated device for spectrometry of heavy charged particles.
  • The semiconductor pixel detector Timepix (256 x 256 pixels with pitch of 55 mu m) is a successor of the Medipix2 device. Each Timepix pixel can be independently operated in one of three possible modes: (1) counting of the detected particles; (2) measurement of the particle energy; and (3) measurement of the time of interaction. The energy measurement in the second mode is performed via the determination of the %22time-over-threshold%22 (TOT). The energy measurement with the Timepix detector in TOT mode requires knowledge of the energy calibration of each pixel of the matrix. Such calibration is very nonlinear in the low energy range and can be described by a surrogate function depending on four parameters. The determination of all these parameters can be performed by measurement and evaluation of the response of each pixel in at least four calibration points. The procedure is extremely demanding: it requires the analysis of at least 250 thousand spectra and the performance of 330 thousand least-squares fits. In this article, it is demonstrated that even better result can be achieved with only two or three calibration points halving the number of least-squares fits needed. The method is based on precise analysis of the shape of spectral peaks. The article also discusses the performance of energy calibrated device for spectrometry of heavy charged particles. (en)
Title
  • Precise energy calibration of pixel detector working in time-over-threshold mode
  • Precise energy calibration of pixel detector working in time-over-threshold mode (en)
skos:prefLabel
  • Precise energy calibration of pixel detector working in time-over-threshold mode
  • Precise energy calibration of pixel detector working in time-over-threshold mode (en)
skos:notation
  • RIV/68407700:21670/11:00191681!RIV12-MSM-21670___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(LC06041), Z(MSM6840770040)
http://linked.open...iv/cisloPeriodika
  • 0
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 222653
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21670/11:00191681
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Pixel detectors; X-ray radiography; Material recognition (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [FCE1933BCFCF]
http://linked.open...i/riv/nazevZdroje
  • Nuclear Instruments and Methods in Physics Research, Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 633
http://linked.open...iv/tvurceVysledku
  • Jakůbek, Jan
http://linked.open...ain/vavai/riv/wos
  • 000292782400077
http://linked.open...n/vavai/riv/zamer
issn
  • 0168-9002
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.nima.2010.06.183
http://localhost/t...ganizacniJednotka
  • 21670
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software