  • X-ray phase contrast imaging using a single absorption grating and a hybrid semiconductor pixel detector is a newly introduced approach with great potential for application in medicine, biology and material research. In comparison with a conventional grating interferometer technique, which requires a multiple-exposure (phase-stepping) procedure, our method is greatly simplified, because both phase gradient and absorption images are obtained from just one exposure. Consequently, the approach can significantly reduce the time-consuming scanning and also possibly the dose. Examples of application of the approach as an imaging tool for investigations in biology are presented. Particularly, we present the extension of our 1-D single grating method to a two-direction sensitive technique. In a single exposure, phase gradient images in two perpendicular directions together with the conventional attenuation image are produced. Results of the proof-of-concept experiment are presented.
  • X-ray phase contrast imaging using a single absorption grating and a hybrid semiconductor pixel detector is a newly introduced approach with great potential for application in medicine, biology and material research. In comparison with a conventional grating interferometer technique, which requires a multiple-exposure (phase-stepping) procedure, our method is greatly simplified, because both phase gradient and absorption images are obtained from just one exposure. Consequently, the approach can significantly reduce the time-consuming scanning and also possibly the dose. Examples of application of the approach as an imaging tool for investigations in biology are presented. Particularly, we present the extension of our 1-D single grating method to a two-direction sensitive technique. In a single exposure, phase gradient images in two perpendicular directions together with the conventional attenuation image are produced. Results of the proof-of-concept experiment are presented. (en)
Title
  • Single grating method for low dose 1-D and 2-D phase contrast X-ray imaging
  • Single grating method for low dose 1-D and 2-D phase contrast X-ray imaging (en)
skos:prefLabel
  • Single grating method for low dose 1-D and 2-D phase contrast X-ray imaging
  • Single grating method for low dose 1-D and 2-D phase contrast X-ray imaging (en)
skos:notation
  • RIV/68407700:21670/11:00174697!RIV12-MSM-21670___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(LC06041), Z(MSM6840770040)
http://linked.open...iv/cisloPeriodika
  • C01073
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 229542
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21670/11:00174697
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • X-ray radiography and digital radiography; Inspection with x-rays; X-ray detectors; Image reconstruction in medical imaging (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • IT - Italská republika
http://linked.open...ontrolniKodProRIV
  • [ACE653FB997B]
http://linked.open...i/riv/nazevZdroje
  • Journal of Instrumentation
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 6
http://linked.open...iv/tvurceVysledku
  • Jakůbek, Jan
  • Krejčí, František
  • Kroupa, Martin
http://linked.open...ain/vavai/riv/wos
  • 000291345600078
http://linked.open...n/vavai/riv/zamer
issn
  • 1748-0221
number of pages
http://bibframe.org/vocab/doi
  • 10.1088/1748-0221/6/01/C01073
http://localhost/t...ganizacniJednotka
  • 21670
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software