About: Enhancement of Spatial Resolution of Roentgenographic Methods Using Deconvolution     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The spatial resolution of X-ray micro radiography is the crucial parameter. Its improvement remains a major experimental and data processing challenge. The lower limit of the spatial resolution of a radiographic method is given by the size of the point spread function (PSF). In the case of high geometrical magnification, the X-ray spot size becomes the most important factor for PSF determination. We have successfully measured in 2-D the X-ray spot shape and using deconvolution the spatial resolution has been improved up to three-fold. We have successfully illustrated the approach for real biological and material structure investigations. Another possibility for resolution enhancement is sub-pixel micro-shifting of the X-ray detector. Although this approach is quite common for optical imaging, it has not been fully investigated for X-ray imaging. In our measurements we have used sub-pixel micro-shifts of the Medipix2 detector. The method is successfully presented on real objects.
  • The spatial resolution of X-ray micro radiography is the crucial parameter. Its improvement remains a major experimental and data processing challenge. The lower limit of the spatial resolution of a radiographic method is given by the size of the point spread function (PSF). In the case of high geometrical magnification, the X-ray spot size becomes the most important factor for PSF determination. We have successfully measured in 2-D the X-ray spot shape and using deconvolution the spatial resolution has been improved up to three-fold. We have successfully illustrated the approach for real biological and material structure investigations. Another possibility for resolution enhancement is sub-pixel micro-shifting of the X-ray detector. Although this approach is quite common for optical imaging, it has not been fully investigated for X-ray imaging. In our measurements we have used sub-pixel micro-shifts of the Medipix2 detector. The method is successfully presented on real objects. (en)
  • Prostorové rozlišení je v mikroradiografii rozhodujícím parametrem. Jeho zlepšování zůstává stálou výzvou jak v oblasti experimentální, tak v oblasti zpracování dat. Prostorové rozlišení je dáno velikostí a tvarem tzv. point spread function (PSF). V případě velkého geometrického zvětšení je hlavním faktorem určujícím PSF tvar rentgenového spotu. Podařilo se nám úspěšně změřit ve 2-D tvar rentgenového zdroje a pomocí dekonvoluce bylo prostorové rozlišení zvětšeno až třikrát. Výsledky jsou prezentovány na reálných objektech v biologii a v materiálovém výzkumu. Další možností pro zvyšování prostorového rozlišení je využití subpixelových posunů detektoru. Přestože tato metoda je poměrně běžně využívána v zobrazování ve viditelné oblasti, pro rentgenové zobrazování nebyla dosud plně popsána. Tato metoda je úspěšně demonstrována na reálných objektech s detektorem Medipix2. (cs)
Title
  • Enhancement of Spatial Resolution of Roentgenographic Methods Using Deconvolution
  • Enhancement of Spatial Resolution of Roentgenographic Methods Using Deconvolution (en)
  • Zvyšování prostorového rozlišení rentgenografických metod pomocí dekonvoluce (cs)
skos:prefLabel
  • Enhancement of Spatial Resolution of Roentgenographic Methods Using Deconvolution
  • Enhancement of Spatial Resolution of Roentgenographic Methods Using Deconvolution (en)
  • Zvyšování prostorového rozlišení rentgenografických metod pomocí dekonvoluce (cs)
skos:notation
  • RIV/68407700:21670/08:15152326!RIV09-MSM-21670___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(LC06041), Z(MSM6840770040)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 366263
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21670/08:15152326
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Medipix2; deconvolution; micro-shifting; spatial resolution; x-ray imaging (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [CAD1940C747E]
http://linked.open...v/mistoKonaniAkce
  • Dresden
http://linked.open...i/riv/mistoVydani
  • Wisconsin
http://linked.open...i/riv/nazevZdroje
  • Conference Record of the 2008 IEEE NSS/MIC/RTSD
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Jakůbek, Jan
  • Vavřík, Daniel
  • Krejčí, František
  • Kroupa, Martin
  • Dammer, Jiří
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
http://linked.open...n/vavai/riv/zamer
issn
  • 1082-3654
number of pages
http://purl.org/ne...btex#hasPublisher
  • Omipress
https://schema.org/isbn
  • 978-1-4244-2715-4
http://localhost/t...ganizacniJednotka
  • 21670
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software