About: Event timing device providing subpicosecond precision     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • We are reporting on the latest experimental results achieved with an event timing device using a surface acoustic wave filter as a time interpolator. During the tests of the first version of the device, the noise of the filter excitation was identified as the dominant source of the measurement error. Therefore a new concept of the excitation with very low level of the noise energy was designed. This new solution led to considerable improvement of the device performance. It results from the experimental measurements that the single shot precision is repeatedly lower than 500 fs RMS when time marks generated synchronously with the time base are measured. When asynchronous time marks are split into two event timers and the resulting time difference is measured, the single shot precision is below 700 fs RMS per channel. In this case the measurement is affected not only by random errors, but also by non-linearity of the time interpolation. The temperature dependence is below 0.1 ps/K. Operating the device in a common laboratory environment without temperature stabilization, the stability TDEV better than 3 fs has been routinely achieved for range of averaging intervals from 10 s to several hours.
  • We are reporting on the latest experimental results achieved with an event timing device using a surface acoustic wave filter as a time interpolator. During the tests of the first version of the device, the noise of the filter excitation was identified as the dominant source of the measurement error. Therefore a new concept of the excitation with very low level of the noise energy was designed. This new solution led to considerable improvement of the device performance. It results from the experimental measurements that the single shot precision is repeatedly lower than 500 fs RMS when time marks generated synchronously with the time base are measured. When asynchronous time marks are split into two event timers and the resulting time difference is measured, the single shot precision is below 700 fs RMS per channel. In this case the measurement is affected not only by random errors, but also by non-linearity of the time interpolation. The temperature dependence is below 0.1 ps/K. Operating the device in a common laboratory environment without temperature stabilization, the stability TDEV better than 3 fs has been routinely achieved for range of averaging intervals from 10 s to several hours. (en)
Title
  • Event timing device providing subpicosecond precision
  • Event timing device providing subpicosecond precision (en)
skos:prefLabel
  • Event timing device providing subpicosecond precision
  • Event timing device providing subpicosecond precision (en)
skos:notation
  • RIV/68407700:21340/13:00214243!RIV14-MSM-21340___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 73741
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21340/13:00214243
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • picosecond timing; femtosecond stability (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [54BDDA774E91]
http://linked.open...v/mistoKonaniAkce
  • Prague
http://linked.open...i/riv/mistoVydani
  • Piscataway
http://linked.open...i/riv/nazevZdroje
  • 2013 Joint European Frequency and Time Forum and International Frequency Control Symposium (EFTF/IFC)
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Kodet, Jan
  • Procházka, Ivan
  • Pánek, Petr
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://bibframe.org/vocab/doi
  • 10.1109/EFTF-IFC.2013.6702120
http://purl.org/ne...btex#hasPublisher
  • IEEE Ultrasonics, Ferroelectrics, and Frequency Control Society
https://schema.org/isbn
  • 978-1-4799-0342-9
http://localhost/t...ganizacniJednotka
  • 21340
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 78 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software