  • The aim of this work is to estimate the homogeneity of the radiation field in various configurations and relative activities of the %22disposed%22 but still relatively highly active sources for their potential use in irradiation of blood (or blood derivatives). Small dose rate, which is already unusable/inappropriate for the teletherapy, may be still utilized by simultaneous use of multiple sources or reducing the distance to the irradiated object (blood unit). To estimate the homogeneity of the radiation field a modeling approach was chosen in which Monte Carlo code MCNP has been employed. (In-) homogeneity of the radiation field has been estimated on the basis of isodoses in the water phantom and various configurations and relative activities of the cobalt sources. The results are further discussed with regard to optimization (homogeneity of the sample irradiation, costs, radiation protection of service staff, availability of a sufficient number of resources, etc.).
  • The aim of this work is to estimate the homogeneity of the radiation field in various configurations and relative activities of the %22disposed%22 but still relatively highly active sources for their potential use in irradiation of blood (or blood derivatives). Small dose rate, which is already unusable/inappropriate for the teletherapy, may be still utilized by simultaneous use of multiple sources or reducing the distance to the irradiated object (blood unit). To estimate the homogeneity of the radiation field a modeling approach was chosen in which Monte Carlo code MCNP has been employed. (In-) homogeneity of the radiation field has been estimated on the basis of isodoses in the water phantom and various configurations and relative activities of the cobalt sources. The results are further discussed with regard to optimization (homogeneity of the sample irradiation, costs, radiation protection of service staff, availability of a sufficient number of resources, etc.). (en)
Title
  • Estimation of the Radiation Field Homogeneity in Co-60 Blood Irradiator
  • Estimation of the Radiation Field Homogeneity in Co-60 Blood Irradiator (en)
skos:prefLabel
  • Estimation of the Radiation Field Homogeneity in Co-60 Blood Irradiator
  • Estimation of the Radiation Field Homogeneity in Co-60 Blood Irradiator (en)
skos:notation
  • RIV/68407700:21340/13:00212313!RIV14-MSM-21340___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(TA02010372), S
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 73299
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21340/13:00212313
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • blood irradiator; homogeneity; Monte Carlo method (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [D790EE49B971]
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Urban, Tomáš
  • Konček, Ondřej
  • Dučevová, Kateřina
http://localhost/t...ganizacniJednotka
  • 21340
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 47 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software